A Multiplex Liquid Array Assay Based on Luminex xTAG Technology for the Detection of Five Respiratory Pathogens in SPF Chickens.
Qiuyang Sun, Yufang Feng, Fangwei Dai, Qiang Gao, Xueqing Zhang, Shanshan Yao, Rui Fu, Chunnan Liang,
Institute of Laboratory Animal Resources (National Rodent Experimental Animal Resource Bank), National Institutes for Drug Control, Beijing 102629, China. · Center of Laboratory Animal, Hangzhou Medical College, Hangzhou 310013, China.
Key points
From the paper's conclusion- A multiplex liquid array assay based on Luminex xTAG technology was developed for the first time for the simultaneous detection of five respiratory bacterial pathogens in Specific Pathogen-Free (SPF) chickens-Mycoplasma gallisepticum (MG), Mycoplasma synoviae (MS), Pasteurella multocida (Pm), Avibacterium paragallinarum (Apg), and Mycobacterium avium (Mav)-filling the gap that these five pathogens
Abstract
A multiplex liquid array assay based on Luminex xTAG technology was developed for the first time for the simultaneous detection of five respiratory bacterial pathogens in Specific Pathogen-Free (SPF) chickens-Mycoplasma gallisepticum (MG), Mycoplasma synoviae (MS), Pasteurella multocida (Pm), Avibacterium paragallinarum (Apg), and Mycobacterium avium (Mav)-filling the gap that these five pathogens could not be simultaneously detected previously. Specific primers were designed targeting conserved genes of each pathogen, with a TAG sequence attached to the 5' end of each forward primer and biotin to the 5' end of each reverse primer. After multiplex PCR amplification, the products were hybridized with MagPlex-TAG microspheres and analyzed using the Luminex system. The method was validated for sensitivity, specificity, and repeatability, and tested with simulated positive samples (a mixture of genomic DNA from the five target pathogens) and SPF chicken samples. The LOD was 10 copies/μL for Pm and 100 copies/μL for the other four pathogens. No cross-reactivity was observed with 18 non-target bacterial species. Intra- and Inter-assay coefficients of variation (CV) ranged from 0.8% to 12.2% and 2.3% to 14.4%, respectively, both below 15%. All simulated mixed positive samples yielded results consistent with expectations, and none of the 114 nasopharyngeal swab samples from SPF chickens tested positive for any of the five targets. The developed assay offers high throughput, high sensitivity, high specificity, and good repeatability, providing a robust tool for routine quality control in SPF chickens.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A multiplex TaqMan real-time PCR assay for differential identification of wild-type and vaccine strains of Mycoplasma gallisepticumPoultry Science · 2026
- Two Pentaplex Real-Time Fluorescent PCR Assays for Simultaneous Detection of Ten Ovine Respiratory and Reproductive Pathogens.Viruses · 2026
- A single-target duplex real-time PCR assay for simultaneous detection and differentiation of Mycoplasma gallisepticum and Mycoplasma synoviae.Avian pathology : journal of the W.V.P.A · 2026
- Complementary detection of respiratory pathogens and antimicrobial-resistance markers by multiplex PCR alongside culture in a High-AMR Egyptian cohort.Journal of applied microbiology · 2026
- Development and validation of a quadruplex real-time quantitative polymerase chain reaction assay for the simultaneous detection of Mycoplasma hyopneumoniae, Mycoplasma hyorhinis, Actinobacillus pleuropneumoniae, and Glaesserella parasuis.Veterinary world · 2026
- A fully automated rotary microfluidic platform for high-throughput multiplex detection of respiratory tract pathogensMicrosystems & Nanoengineering · 2025