Excitation-Selective Red–Near-Infrared Luminescence and Optical Thermometry of Nominally Undoped GAGG Ceramic with Trace Cr and Fe from 12 to 300 K
Zhakyp T. Karipbayev, Akbota Tolegenova, Dossymkhan A. Mussakhanov, Amangeldy M. Zhunusbekov, Abylay S. Kobey, Zhanna A. Akdavletova, Symbat Ospanova, Anatoli I. Popov
Key points
From the paper's conclusion- The results establish excitation and spectral-window selection as practical controls for internally referenced temperature readout in a ceramic prepared without intentional activator addition.
Abstract
A nominally undoped Gd3Al2Ga3O12 (GAGG) ceramic was prepared by solid-state processing in air at 1700 °C for 10 h without deliberate activator or coactivator addition. Constrained Rietveld refinement identifies predominant cubic garnet with a = 12.2596(12) Å, conditional on the specimen-displacement model, while SEM–EDS documents faceted grains and weak, semiquantitative Cr and Fe signals. Synchrotron and laboratory excitation spectra distinguish a broad host-related response near 200–211 nm from narrow Gd3+ features and visible Cr-related excitation bands. Temperature readout was evaluated under 160, 206 and 222 nm excitation using fixed spectral ratios and the position of the narrow feature near 694 nm. Under 206 nm excitation, the 750–850/640–740 nm integral ratio is monotonic at 16 temperatures from 12 to 300 K, with empirical relative sensitivity 0.310% K−1 and an internal leave-one-temperature-out root-mean-square error of 8.16 K. For the separate 160–300 K sequence, the 694 nm position gives 2.52 K under the same excitation. At 222 nm, selecting the local 708–720/688–700 nm ratio instead of NIR/red reduces the internal error from 43.05 to 4.32 K over 160–300 K. Apparent red-line quenching barriers are 53.2–60.8 meV. Room-temperature decay times of 212–232 μs under 450 nm excitation and 5.516 ms under 280 nm excitation constrain the relaxation pathways. The results establish excitation and spectral-window selection as practical controls for internally referenced temperature readout in a ceramic prepared without intentional activator addition. The reported errors describe internal validation of specimen-specific calibrations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Energy Transfer Engineering Enables Efficient Near‐Infrared Luminescence and Zero‐Thermal‐Quenching in GAGG: Fe 3+ , Yb 3+ PhosphorsLaser & Photonics Reviews · 2026
- Multi‐site regulation of Gd garnet for lattice stabilization and efficient/thermally stable broadband Cr³⁺ luminescenceJournal of the American Ceramic Society · 2025
- Synchrotron-Based UV–VUV Excitation and Time-Resolved Luminescence of MgGa2O4 CeramicsMaterials · 2026
- Thermodynamic Stabilization and Cr³⁺ Luminescence Tuning in Gd₃ Al₅ O₁₂ Garnet Phosphor via Multi‐Cation IncorporationJournal of the American Ceramic Society · 2026
- Soft Lattice and Dual-Emitter Engineering in Cr³⁺ -Doped Fluorides: Achieving Highly Sensitive and High-Fidelity Near-Infrared Optical ThermometryInorganic Chemistry · 2026
- Emergence of Unusual Cr³⁺ Emission and Exceptional Thermal Stability in Ca₃ Ga₂ Ge₃ O₁₂ : Cr³⁺ /Yb³⁺ Garnet Phosphors for High-Performance Optical Thermometry and NIR pc-LEDsACS Applied Optical Materials · 2026