TinyML Benchmarking for Embedded sEMG Gesture Classification: Quantized Model Design and an Accessible Robotic Hand Prosthesis Demonstration

Cesar Hernando Valencia Nino, Ronald Yessid Alvarez Suarez, Yennzy Camila Barrera Ardila, Juan Jose Lopez Mier, Cristhiam Jesid Gutierrez Lozano

Computational

Key points

From the paper's conclusion
  • Embedded operation and a qualitative functional demonstration on the physical prosthesis, assessed by visual observation rather than instrumented kinematics, grasp force or task-success measurements, confirmed feasibility, while cross-subject validation, direct on-device latency measurements and component-wise ablation remain necessary before clinical or daily-use claims.

Abstract

Surface electromyography (sEMG) enables non-invasive prosthetic control, but deployment is limited by non-stationary signals, noise and embedded-computing constraints. This work presents a mathematically defined pipeline for real-time control of an accessible, commodity-component robotic hand prosthesis (no formal bill-of-materials or aggregate cost figure is claimed) from eight-channel Myo Armband sEMG, together with a deployment-oriented benchmarking study of quantized TinyML classifiers, benchmarked independently of the physical prosthesis rather than executed on it. The sEMG stream is filtered, windowed and classified by a hybrid CNN-BiLSTM reference model, converting posterior probabilities into PWM prosthetic commands on a Raspberry Pi. Five gesture classes were considered, using data from a single able-bodied participant, framed as a within-subject feasibility study. From 167,712 labeled samples, the reference model reached 99.6% test accuracy (99.58% macro F1) on a session-disjoint split. Because this reference model targets a Raspberry Pi rather than a microcontroller, four quantized TinyML candidates (TCN ensemble, embedded-C Random Forest, MLP ensemble, decision tree) were additionally designed and benchmarked under a common accuracy-footprint-inference-time protocol. Quantization cost was substantial: the deployed int8 TCN reached 83.5% smoothed accuracy versus 90.1% float32, while an embedded-C Random Forest reached 90.7% at only 17.9 KB. SHAP analysis revealed model-dependent channel importance patterns, with the TCN ensemble and the Random Forest ranking electrode channels differently because they exploit different signal representations. Embedded operation and a qualitative functional demonstration on the physical prosthesis, assessed by visual observation rather than instrumented kinematics, grasp force or task-success measurements, confirmed feasibility, while cross-subject validation, direct on-device latency measurements and component-wise ablation remain necessary before clinical or daily-use claims.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers