Quantifying Carbon Abatement from Campus Solar Photovoltaics: An Empirical Case Study
Rafe Alasem, Ruhi Sethi, Maher Alrahhal, Saher Nabi
Key points
From the paper's conclusion- This study examines the available monthly records associated with the five-array PV fleet at Amity University Dubai, United Arab Emirates, from January 2022 to August 2026.
Abstract
Campus photovoltaic (PV) systems are often credited with a single avoided-emissions figure, although the result depends on the grid factor selected and on what the metering records actually represent. This study examines the available monthly records associated with the five-array PV fleet at Amity University Dubai, United Arab Emirates, from January 2022 to August 2026. The supplied workbook totals 4.62 GWh across 56 monthly entries; however, the workbook labels and billing dates do not independently verify that all entries represent calendar-month PV production measured at the same meter. The March–April 2026 shortfall is unexplained and may be affected by billing-period differences. Five emission-factor scenarios are evaluated: year-matched Dubai Electricity and Water Authority (DEWA) averages, an illustrative transmission-and-distribution-loss adjustment, and International Financial Institution (IFI) operating-, combined- and derived build-margin factors for the UAE. Under the full-displacement assumption, the DEWA-average scenario gives approximately 1826 t of estimated gross avoided emissions; alternative IFI scenarios produce materially different results. The Monte Carlo interval reflects only the analyst-selected meter and factor-error distributions and is not a measure of total uncertainty. Because meter-period definitions, self-consumption, exports, curtailment and the relevant contractual arrangements are not established, the results are conditional screening estimates, not measurements of realized avoided emissions or verified Scope 2 reductions. This study provides a scenario-based accounting framework and identifies the evidence needed for a more defensible assessment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Temporal resolution matters: Evaluating carbon emission factors for accurate accounting in commercial buildingsApplied Energy · 2026
- Uncertainty-aware electrification of university campuses: Matching demand with renewable generation for zero emissions.Engineering science and technology · 2026
- Carbon Footprint of King Saud University’s Main Campus: Challenges Toward Carbon NeutralitySustainability · 2026
- Study of a University Campus Smart Microgrid That Contains Photovoltaics and Battery Storage with Zero Feed-In OperationSolar · 2026
- Geometry-Conditioned Conformal Calibration for Guaranteed False-Alarm Control in Uncertain Nonlinear Photovoltaic SystemsApplied Sciences · 2026
- Techno-Economic and Environmental Assessment of a Hybrid Photovoltaic–Diesel–Grid System for University FacilitiesProcesses · 2026