Beyond the Biological Ceiling: Lessons from Scaffold-Guided Reconstruction of a 33 cm Femoral Defect
Ahmed Al Ghaithi, Humaid Al Farii, Mohammed Al Mutani, Asem Shalaby, Sultan Al Maskari
Key points
From the paper's conclusion- We propose three plausible contributors—a defect at the upper limit of reported clinical experience without axial vascular supply, a scarred and hypovascular host bed, and a staged bioactivation protocol requiring repeated surgical re-entry, which was temporally associated with infection.
Abstract
Case: A 20-year-old man carried a 33 cm diaphyseal femoral defect after childhood osteosarcoma and three failed reconstructions—distraction osteogenesis, autografting, and the induced-membrane (Masquelet) technique. As a final limb-salvage attempt, a patient-specific 3D-printed polycaprolactone–tricalcium phosphate (PCL-TCP) scaffold was implanted over an intramedullary nail and bioactivated with iliac-crest bone marrow aspirate, followed at nine months by reamer–irrigator–aspirator autograft. Biopsy at the RIA procedure confirmed new osteoid and thick-walled vessels at the scaffold interface, yet radiographic consolidation never followed. Four weeks later, Staphylococcus haemolyticus infection supervened, and after serial debridement the scaffold was explanted. At four years, the limb is preserved, and the patient walks independently with a mild limp and a radiographically fused knee. Conclusions: Histological osteogenesis without radiographic union suggests a construct that was biologically active but outpaced by the size of the defect. We propose three plausible contributors—a defect at the upper limit of reported clinical experience without axial vascular supply, a scarred and hypovascular host bed, and a staged bioactivation protocol requiring repeated surgical re-entry, which was temporally associated with infection. Their individual effects cannot be separated in a single case, but they suggest that defect length, host vascularity and cumulative infection exposure, and not scaffold chemistry alone, should inform candidate selection for this technology.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Reconstruction of an extensive infection-related femoral segmental bone defect using a customized 3D-printed porous titanium scaffold and a free vascularized fibular flap: a case report and literature reviewBMC Musculoskeletal Disorders · 2026
- Long-term follow-up of patients with large segmental bone defects treated with 3D-printed polycaprolactone/tricalcium phosphate scaffoldsEuropean Journal of Trauma and Emergency Surgery · 2025
- Bioadhesive-Integrated 3D-Printed Multilayer Scaffolds Secure a Mechanically-Stable Osteoimmune Niche for Enhanced Bone Augmentation.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2026
- Use of a 3D-Printed Personal Graft Cage in Treatment of Critical Size Bone Defects: Case Report for an Open Type 3 Distal Femur Fracture.JBJS case connector · 2026
- Solvent-Free 3D PCL/HA Scaffold With a Modified Cationic Polymer Interface for Synchronized Antibacterial Activity and Personalized Bone Regeneration.Macromolecular bioscience · 2026
- Case Report: Massive allograft resorption after reconstruction of large fibular bone defect secondary to osteomyelitis.Frontiers in pediatrics · 2026