Measurement Properties of the Official Modern Standard Arabic Borg CR Scale® (CR10) for Assessing Perceived Exertion.
Mohamed Ali Baccouche, Achraf Ammar, Liwa Masmoudi, Mohamed Kerkeni, Haitham Jahrami, Hamdi Chtourou, Khaled Trabelsi
High Institute of Sport and Physical Education of Sfax, University of Sfax, Sfax 3000, Tunisia. · Department of Training and Movement Science, Institute of Sport Science, Johannes Gutenberg University Mainz, 55122 Mainz, Germany.
Key points
From the paper's conclusion- These findings support the measurement properties examined for the Arabic CR10 in Arabic-speaking Tunisian adults under standardized incremental cycling conditions.
Abstract
An official Modern Standard Arabic version of the Borg CR Scale® (CR10) is available, but evidence on its measurement properties remains limited. This study evaluated measurement properties of the official Arabic CR10 without modification. Phase 1 involved cognitive interviews with 48 participants. Phase 2 comprised an experimental session (T1; n = 72) and a retest 7 ± 2 days later (T2; n = 52). Convergent validity was examined during ramp-incremental cycling using associations with work rate and heart rate (HR). Recovery was analyzed using a linear mixed-effects model. Test-retest reliability was assessed using the intraclass correlation coefficient [ICC(A,1)], Bland-Altman analysis, standard error of measurement (SEM), and minimal detectable change at the 95% confidence level (MDC95). Correct comprehension was 95.8%, and favorable acceptability was 93.8%. CR10 ratings were strongly associated with work rate (r_rm = 0.91; 95% CI, 0.89-0.93) and HR (r_rm = 0.86; 95% CI, 0.83-0.89; both p < 0.001). During recovery, HR remained positively associated with CR10 (β = 0.048 per bpm; 95% CI, 0.037-0.059; p < 0.001). Peak CR10 showed good test-retest reliability (ICC(A,1) = 0.82; 95% CI, 0.71-0.89), minimal bias (-0.08), SEM = 0.49, and MDC95 = 1.35. These findings support the measurement properties examined for the Arabic CR10 in Arabic-speaking Tunisian adults under standardized incremental cycling conditions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Inter-rater Reliability of Physiological and Pressure Pain Threshold Measurements During the Assessment of the Requiescence Technique in Healthy Young Adults.Cureus · 2026
- Psychometric evaluation of an adapted Arabic version of the Global Physical Activity Questionnaire (GPAQ-AR).Frontiers in sports and active living · 2026
- Development and Clinical Application of CPAP-Specific Patient-Reported Outcome Measures in Obstructive Sleep Apnea.Respiratory care · 2026
- Associations Between an Individualized Heart Rate-Based Training Index and Mood States in Elite Female Kendo Athletes: An Exploratory Field Study.Sports (Basel, Switzerland) · 2026
- Between-visit Reproducibility of Cerebrovascular and Cardiovascular Reactivity During the Cold Pressor Test.American journal of physiology. Heart and circulatory physiology · 2026
- Turkish validity and reliability of the Migraine Treatment Optimization Questionnaire-4 (MTOQ-4).BMC neurology · 2026