Machine Learning for Photovoltaic Partial-Shading Diagnosis from Current-Voltage Curves
Retselisitsoe David Pebane, Bonginkosi A. Thango
Key points
From the paper's conclusion- The results establish reproducible controlled-domain discrimination and uncertainty sensitivity, but external measured-data validation across irradiance, modules, array configurations, and shadow geometries remains necessary before deployment.
Abstract
Partial shading deforms photovoltaic (PV) current–voltage (I-V) characteristics and complicates reliable condition monitoring. This study develops and stress-tests a compact, feature-based machine-learning framework using a public model-generated I-V dataset. The primary cohort contains 186 curves at 1000 W m−2, balanced across uniform operation and five nominal shading severities (10%, 20%, 30%, 40%, and 50%) at 31 temperatures from 20 to 50 °C. A verified set of 37 electrical, normalized, maximum-power-point, and curve-shape predictors was evaluated with six classifiers under 30 repeated stratified temperature-grouped five-fold validations, followed by nested grouped confirmation. The selected 10-feature logistic-regression model achieved 1.000 accuracy, balanced accuracy, macro-F1, Matthews correlation coefficient, Cohen’s κ, and ROC-AUC for binary and six-class diagnosis; the temperature-group bootstrap 95% confidence interval for macro-F1 was 1.000–1.000. A single normalized maximum-power-point-voltage predictor also achieved macro-F1 = 1.000, showing that the controlled source domain is strongly and partly rule-separable. The clean high-C solution was highly sensitive to measurement disturbance: under a 5% combined bias, drift, Gaussian, and quantization stress test, mean macro-F1 fell to 0.395 for binary detection and 0.095 for six-class diagnosis, whereas noise-aware training remained 0.976 and 0.962, respectively. Normalized maximum-power-point voltage, fill factor, maximum-power-point voltage, and maximum-power-point power were the dominant features. A uniform-operation negative control across 500–1000 W m−2 also exposed irradiance-domain sensitivity in the noise-aware model. The results establish reproducible controlled-domain discrimination and uncertainty sensitivity, but external measured-data validation across irradiance, modules, array configurations, and shadow geometries remains necessary before deployment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- AI‐Based PV Fault Detection: Benchmarking Indicators and Feature Selection MethodsProgress in Photovoltaics: Research and Applications · 2026
- Photovoltaic Condition Assessment from I–V Curve Shape Alone: A Generic Normalized Reference ApproachEnergies · 2026
- A hybrid framework for photovoltaic array anomaly dataset partitioning combining unsupervised clustering and statistical methodsInternational Journal of Green Energy · 2026
- An Irradiance-Normalized Current-Collapse Index for Diagnosing Current-Limited Power Loss in Photovoltaic ModulesEngineering Research Express · 2026
- Fault detection and diagnosis in photovoltaic systems using artificial intelligence and time–frequency analysisScientific Reports · 2026
- Physics-Informed Photovoltaic Fault Diagnosis Using Hard-Clamped Feature Engineering and Progressive Fine-TuningApplied Sciences · 2026