ML-CDAE: Multi-Lead Convolutional Denoising Autoencoder for Denoising 12-Lead ECG Signals
Malaz Alfa, Fars Samann, Thomas Schanze
Technische Hochschule Mittelhessen · University of Duhok
Key points
From the paper's conclusion- Therefore, a multi-lead convolutional denoising autoencoder (ML-CDAE) model is proposed, to learn more effective representations, leading simultaneously to improved denoising performance and enhanced quality of 12-lead ECG recordings.
Abstract
Background: Electrocardiography (ECG), particularly the 12-lead configuration, is a crucial method for identifying heart rhythm abnormalities. However, its effectiveness can be reduced by noise contamination. State-of-the-art denoising methods based on neural networks have demonstrated promising performance in denoising complex biosignals like ECG. However, most of these methods have focused on denoising single-lead ECG recordings. Methods: This research aims to leverage the inherent correlation among multi-lead ECG signals. Therefore, a multi-lead convolutional denoising autoencoder (ML-CDAE) model is proposed, to learn more effective representations, leading simultaneously to improved denoising performance and enhanced quality of 12-lead ECG recordings. Results: The findings indicate that ML-CDAE consistently outperforms a single-lead convolutional denoising autoencoder (SL-CDAE) and fully convolutional denoising autoencoder (FCN-DAE) model in denoising ECG signals corrupted by a mixture of physical noises. In particular, the mean squared error (MSE) and signal-to-noise ratio improvement (SNRimp) are used as evaluation metrics to assess the performance. Conclusions: The strong correlation among multi-lead ECG signals can be leveraged not only to enhance the denoising performance of the ML-CDAE model but also to simultaneously denoise 12-lead ECG signals more successfully compared to both the SL-CDAE and FCN-DAE models.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- 12-lead ECG synthesis from reduced lead set using multi-lead convolutional autoencoderCurrent Directions in Biomedical Engineering · 2026
- Improving ECG diagnostic performance under ambulatory noise with scalable long-range state-space denoising modellingEuropean Heart Journal · 2026
- ECG-ARD: Autoregressive ECG Denoising With Dual-Domain Fusion and a Vector-Quantized Bottleneck.IEEE journal of biomedical and health informatics · 2026
- DR-net-Mamba: Selective State-Space Modeling for Long-Range ECG Time-Series DenoisingarXiv · 2026
- BiMa-ECGSR: reconstructing the 12-lead ECG from reduced lead sets with bidirectional state-space modelsarXiv · 2026
- Comparative Performance Assessment of Stationary Wavelet Transform Configurations for ECG Denoising Using Multi-Metric Evaluation Framework.Sensors (Basel, Switzerland) · 2026