Online Supercritical Fluid Extraction Coupled with Inductively Coupled Plasma Mass Spectrometry for Monitoring Titanium Release from Orthopedic Implants
Tirath Shah, Ankur Patel, Jignesh Shah, Darshil Shah
Key points
From the paper's conclusion- Objective: To develop and evaluate a 3,4,3-(LI-1,2-hydroxypyridinone)-assisted online supercritical fluid extraction–ICP-MS method for the determination of extractable titanium released from commercially pure titanium and Ti-6Al-4V implants.
Abstract
Background: Titanium-based orthopedic implants can release titanium in chloride, acidic and protein-containing biological environments. Conventional acid-digestion ICP-MS can be used to determine the total titanium content released from the implants, but requires substantial mineral-acid consumption and multiple sample-handling steps. Objective: To develop and evaluate a 3,4,3-(LI-1,2-hydroxypyridinone)-assisted online supercritical fluid extraction–ICP-MS method for the determination of extractable titanium released from commercially pure titanium and Ti-6Al-4V implants. Methods: Implant samples were incubated for 21 days in phosphate-buffered saline, simulated body fluid, acidic inflammatory medium, and an albumin-containing matrix. Extraction temperature, pressure, time, pH, modifier, and ligand concentration were optimized. Linearity, detection and quantification limits, recovery, precision, matrix effects, carryover, robustness, and stability were assessed. Results: Optimal extraction was achieved at 60 °C, 25 MPa, 20 min, pH 5.5, 15% methanol, and 50 µmol L−1 ligand. The method was linear over 0.10–5.00 µg L−1, with R2 values of 0.9987 and 0.9979 in phosphate-buffered saline and albumin matrix, respectively. Using the 3σ/S, detection limits were 0.033 and 0.044 µg L−1. Recoveries were 98.4–101.2% and 94.2–96.1%, respectively. Titanium release increased with time and was highest under acidic conditions. Ti-6Al-4V consistently released slightly more titanium than commercially pure titanium across the evaluated model media. Conclusions: The method reduced acid use and handling, but requires specialized high-pressure instrumentation. Conventional acid-digestion ICP-MS remains more accessible for routine total titanium analysis. Clinical-matrix and tribocorrosion validation remain necessary.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Titanium Degradation Products from Dental Implants: Mechanisms of Release, Biodistribution, and Analytical Detection in Biological Matrices.International journal of molecular sciences · 2026
- Supercritical Solution Impregnation: A Strategy to Prevent Prosthetic Infections.Global challenges (Hoboken, NJ) · 2026
- Implantable Polymer-Based Medical Devices Go Supercritical: From Cleaning to Sterilization.Annals of biomedical engineering · 2026
- Evaluation of reagents for suspension-assisted total reflection X-ray fluorescence element analysis in biomedical samplesAnalytical and Bioanalytical Chemistry · 2026
- Redefining Post-detoxification with Novel Surface Coatings: Proteomic Insights into the Early Host Response.ACS biomaterials science & engineering · 2026
- New developments of biomedical porous titanium alloys prepared by spark plasma sinteringMetals Advances · 2026