Assessment of the Applicability of the Protocol for the Safety Removal of Post-Seismic Shorings: Historical Masonry Case Studies
Marianna Rotilio, Giulia D’Alberto, Angelo Di Egidio
Key points
From the paper's conclusion- The three applications illustrate the protocol’s adaptability to varying levels of damage in masonry buildings, including situations where safety shorings were employed solely as a precaution rather than out of necessity.
Abstract
Seismic activity in historic town centers has significantly impacted ancient masonry structures, often leading to extensive damage. To reduce the likelihood of collapse and safeguard both individuals and buildings prior to restoration, temporary shoring systems have been widely implemented. These situations have spurred numerous investigations into the design and installation of such supports, taking into account the different rigid failure mechanisms that can affect walls or sections of masonry buildings. However, the key aspects related to the dismantling of these shoring systems, which play a crucial role in the safety, logistical planning, and cost-efficiency of the repair process, have so far received little attention. The authors of this paper previously developed a protocol for the safe removal of provisional post-seismic shoring systems. The aim of this paper is to assess the applicability of the protocol through its retrospective application to three case studies, each involving historic masonry buildings in L’Aquila, Italy. The three applications illustrate the protocol’s adaptability to varying levels of damage in masonry buildings, including situations where safety shorings were employed solely as a precaution rather than out of necessity. Moreover, the method’s flexibility, enabled by a wide range of possible combinations of mandatory and optional preventive interventions, may facilitate the coordination of the shoring-removal process with the stages of the restoration design, potentially supporting more efficient operational planning. Since the proposed dismantling strategies were not implemented and independently verified, the study assesses the applicability and internal consistency of the procedure but does not constitute an experimental validation of index λ or of the effectiveness of the proposed interventions.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- The effect of existing damage on the seismic performance of a historical masonry structure: a site-specific assessmentBulletin of Earthquake Engineering · 2026
- Structural Control for the Seismic Protection of Cultural Heritage: State of the Art and Review of Full-Scale ApplicationsHeritage · 2026
- Soluções de escavação e contenção periférica com recalçamento de fachada de um edifício histórico em LisboaGeotecnia · 2026
- A deformation-based criterion for redistribution of seismic forces in masonry buildings after linear analysisBulletin of Earthquake Engineering · 2026
- Seismic performance assessment and strengthening of a residential RC building damaged in the 2023 Türkiye Earthquakes: A case studyScientific Reports · 2026
- Post-earthquake damage assessment of a historic masonry fortress: Ravanda castle after the 2023 Kahramanmaraş earthquakesCase Studies in Construction Materials · 2026