Sensors

AI-Enabled Multimodal Sensing of Blink-Evoked Neural and Cardiac Dynamics for Mild Traumatic Brain Injury Assessment

Quintin Peters, Britney Ming, Alec Anzalone, Emily Acampora, Careesa Chang Liu, Sujoy Ghosh Hajra

Key points

From the paper's conclusion
  • These findings suggest that blink-locked brain–heart dynamics warrant further investigation as a biosensing approach and, pending validation in larger independent cohorts, provide a foundation for developing non-invasive sensor systems for objective mTBI assessment.

Abstract

Mild traumatic brain injury (mTBI) largely lacks objective sensor-derived measures of its physiological consequences. We developed an AI-enabled multimodal biosensing framework that uses blinks as natural physiological perturbations to synchronize electroencephalography (EEG) and electrocardiography (ECG). The multimodal sensor framework extracts blink-related neural oscillations (BROs) and cardiac dynamics (BRCDs) to jointly characterize mTBI-related alterations in brain–heart physiology. Simultaneous EEG and ECG were acquired from 70 participants (44 mTBI and 26 controls) during an auditory oddball task. Data were first preprocessed, and spontaneous blink instances were identified using a convolution-based template-matching procedure. Sensor data were segmented with respect to blink occurrences to isolate BROs and BRCDs. Conventional measures, including P300 event-related potentials, heart rate, and heart rate variability, were also derived for comparison. Support vector machine classifiers with nested cross-validation were used to evaluate the ability of blink-related, conventional, and combined feature sets to discriminate mTBI from healthy controls. Compared to healthy controls, mTBI exhibited reduced BRO amplitude during the post-blink interval (p = 0.007), reduced peak-to-peak BRO amplitude (p < 0.01), and prolonged BRO response latency (p = 0.043). In contrast, none of the conventional measures showed any significant differences between the groups. Classification using blink-related sensor features achieved 81% accuracy (AUC = 0.86), exceeding performance using conventional (62% accuracy; AUC = 0.50) and combined features (71% accuracy; AUC = 0.72). These results demonstrate that blink-related metrics exhibit greater discriminative power for capturing altered cortical and autonomic dynamics in mTBI than conventional measures. Utilizing a single-site acute cohort of mTBI individuals, this study provides the first application of blink-evoked EEG–ECG sensing in the classification of mTBI. By combining neural and cardiac sensors with spontaneous blinks and machine-learning-based pattern recognition, the proposed framework shows physiological group differences that were not captured by conventional measures. These findings suggest that blink-locked brain–heart dynamics warrant further investigation as a biosensing approach and, pending validation in larger independent cohorts, provide a foundation for developing non-invasive sensor systems for objective mTBI assessment.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

AI-Enabled Multimodal Sensing of Blink-Evoked Neural and Cardiac Dynamics for Mild Traumatic Brain Injury Assessment — Science Skim