Sensors (Basel, Switzerland)

A Pulse Ahead: Cross-Modal Knowledge Distillation from Arterial Blood Pressure to Photoplethysmography for Compensatory Reserve Prediction.

Benjamin J McCloskey, Michael L Tibbs, Lonnie G Petersen

Aerospace Physiology Lab, Department of Aeronautics and Astronautics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA. · United States Air Force.

Key points

From the paper's conclusion
  • We present a cross-modal distillation framework that aligns PPG representations with embeddings from ABP-trained CRM Vision Transformer (ViT) teachers, transferring arterial waveform information to PPG.

Abstract

The Compensatory Reserve Measurement (CRM) provides high-fidelity situational awareness of a patient's proximity to hemodynamic decompensation, yet existing CRM models depend on arterial blood pressure (ABP) waveforms that are largely inaccessible in prehospital settings. Photoplethysmography (PPG) offers a field-deployable alternative, but state-of-the-art CRM models are trained on ABP waveforms. Prior efforts have therefore forwarded PPG through ABP-trained convolutional networks, producing out-of-distribution predictions. We present a cross-modal distillation framework that aligns PPG representations with embeddings from ABP-trained CRM Vision Transformer (ViT) teachers, transferring arterial waveform information to PPG. Time-aligned ABP and PPG waveforms were collected from nine human subjects during graded lower body negative pressure (LBNP) simulating progressive hemorrhage, both on the ground and during aeromedical evacuation flight. A lightweight transformer student encoder was trained using latent representation alignment and fine-tuned for CRM regression on PPG inputs alone. The model achieved an R2 of 0.616 on held-out subjects (0.714 ground, 0.525 flight), substantially outperforming the direct application of the ABP-trained model on PPG (R2=-0.264). The detection of critically low CRM yielded an area under the curve of 0.92, and predicted CRM tracked LBNP more closely than the arterial teacher (Spearman ρ=0.791 vs. 0.691). These findings support the feasibility of PPG-based CRM estimation for physiological monitoring during emergency first response.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

A Pulse Ahead: Cross-Modal Knowledge Distillation from Arterial Blood Pressure to Photoplethysmography for Compensatory Reserve Prediction — Science Skim