Sensors (Basel, Switzerland)

Smartphone-Based Markerless Motion Capture for Lower-Limb Biomechanical Assessment in Sport and Rehabilitation: A Scoping Review of Tool Diversity and Validation Practice.

Ziqi Gong, Hang Ma, Takuichi Nishimura, Koki Ijuin

Graduate School of Advanced Science and Technology, Japan Advanced Institute of Science and Technology, 1-1 Asahidai, Nomi 923-1292, Ishikawa, Japan.

Review

Key points

From the paper's conclusion
  • Among 46 studies referenced against three-dimensional motion-capture systems, the joints and planes reported differed systematically between reconstruction approaches: 1 of 21 two-dimensional studies reported pelvic angles and none reported a transverse-plane variable, compared with 5 and 10, respectively, of 14 OpenCap studies.

Abstract

Smartphone cameras are now widely used for lower-limb biomechanical assessment, yet the field spans heterogeneous tools and reports validity inconsistently. This scoping review mapped tools, populations, tasks and validation practices across the full spectrum of smartphone-based approaches, deliberately including marker-based and hybrid workflows alongside markerless ones. Following JBI methodology and PRISMA-ScR, PubMed, Scopus and IEEE Xplore were searched on 23 April 2026, with a supplementary search on 8 May 2026, for studies published between 1 January 2019 and 30 April 2026; the reference lists of included studies were also screened. In total, 128 studies were included. Markerless approaches predominated (110, 85.9%), and marker-based or hybrid workflows were used in 18 studies (14.1%). Pose-estimation models were used either within the OpenCap pipeline (24 studies) or within pipelines built by the study authors (59), and 32 studies used manual or semi-automatic digitization. Gait was the primary task in 57 studies (44.5%), whereas one study examined a cutting task. No validity metric family was reported by a majority of studies, and 21 (16.4%) reported none. Among 46 studies referenced against three-dimensional motion-capture systems, the joints and planes reported differed systematically between reconstruction approaches: 1 of 21 two-dimensional studies reported pelvic angles and none reported a transverse-plane variable, compared with 5 and 10, respectively, of 14 OpenCap studies.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Smartphone-Based Markerless Motion Capture for Lower-Limb Biomechanical Assessment in Sport and Rehabilitation: A Scoping Review of Tool Diversity and Validation Practice — Science Skim