Development and Evaluation of a Cap-Mounted Tripolar Concentric Ring Electrode System with a Central Gel-Delivery Opening for tEEG and EEG Recording.
Maryam Norouzi, Behtom Adeli, Walter Besio
Department of Mechanical, Industrial and Systems Engineering, University of Rhode Island, Kingston, RI 02881, USA. · Department of Electrical, Computer and Biomedical Engineering, University of Rhode Island, Kingston, RI 02881, USA.
Key points
From the paper's conclusion- These findings support the feasibility of acquiring tEEG and eEEG signals using the modified TCRE system at hair-bearing scalp locations.
Abstract
Electroencephalography (EEG) commonly uses conventional disc electrodes with conductive gel or paste to record electrical activity from the scalp. However, conventional disc electrodes have limited spatial selectivity because they detect electrical activity spreading from different brain regions. Tripolar concentric ring electrodes (TCREs) have been developed to improve spatial selectivity by estimating the scalp surface Laplacian. Nevertheless, establishing electrical contact at hair-bearing scalp locations remains challenging. To address this challenge, we developed a modified gold-plated copper TCRE with a 2 mm central opening for conductive gel delivery and a custom 3D-printed cap-mounted holder. After electrode placement, conductive gel is delivered through the opening to establish electrical contact between the metallic contacts and the scalp beneath the hair. The system was evaluated in ten healthy adults using eyes-open/eyes-closed resting-state EEG and pattern-reversal checkerboard visual stimulation. For the experimental recordings, two modified TCREs were positioned at the occipital scalp locations O1 and O2, where conductive gel was delivered through their central openings to establish electrical contact with the scalp. A third TCRE was positioned at Pz and coupled using conductive paste, while a separate conventional disc electrode was placed 1 cm superior to Pz. Recordings from these electrode configurations were analyzed to evaluate resting-state alpha activity, visual evoked potentials (VEPs), and signal quality. Each TCRE provided tripolar EEG (tEEG) and EEG Emulator (eEEG) signals. The modified TCREs recorded identifiable VEP components, with negative and positive peaks near 105 and 141 ms, respectively, along with stimulus-related spectral activity. The eEEG VEP waveforms at O1 and O2 showed strong correlations with Pz eEEG (median r=0.897 and 0.938, respectively). Alpha-band power also increased significantly during eye closure in both gel-coupled tEEG channels (Holm-adjusted p=0.0195). Impedance measurements, signal-quality analyses, and circuit modeling provided additional characterization of the system. These findings support the feasibility of acquiring tEEG and eEEG signals using the modified TCRE system at hair-bearing scalp locations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Design and Test Novel EEG Electrode Attachments for Type 4 Afro-textured HairstylesbioRxiv · 2026
- Hair-compatible adhesive hydrogel electrodes for electroencephalography-based cybersickness detection and closed-loop mitigation.Biosensors & bioelectronics · 2026
- A Pilot Study of the Feasibility of In-Ear EEG for Long-Term Temporal Lobe Brain Wave Monitoring.Sensors (Basel, Switzerland) · 2026
- Near-Zero Creep Ionic Elastomer for Non-drifting Ear Electroencephalogram Signal Acquisition.Nature communications · 2026
- The Dry Truth: Hair-Wetting Improves Dry Electrode EEG Signal QualitybioRxiv · 2026
- A Soft Sponge-Pillar Electrode Platform for Motion-Tolerant Ambulatory EEG and Sleep Monitoring.ArXiv · 2026