Sensors (Basel, Switzerland)

Frequency Shift Imaging Using an Adiabatic SLR Self-Refocused Pulse for Positive-Contrast SPION Imaging at 7T.

Akbar Alipour, Madison Chiu, Judy Alper, Hadrien Dyvorne, Gaurav Verma, Shams Rashid, Abraham J P Teunissen, Zahi A Fayad,

BioMedical Engineering and Imaging Institute (BMEII), Icahn School of Medicine at Mount Sinai, New York, NY 10029, USA.

Key points

From the paper's conclusion
  • This study introduces Frequency Shift Imaging (FSI), a positive-contrast technique based on an adiabatic Shinnar-Le Roux (SLR) self-refocused pulse that addresses the limited specificity of conventional SPION imaging.

Abstract

PURPOSE: Superparamagnetic iron oxide nanoparticles (SPION) are widely used as MRI contrast agents for cell tracking and molecular imaging. However, their detection using conventional T2/T2* weighted and susceptibility-weighted MRI relies on negative contrast (signal voids), which lacks specificity because similar hypointense signals can arise from other sources of magnetic susceptibility. This study introduces Frequency Shift Imaging (FSI), a positive-contrast technique based on an adiabatic Shinnar-Le Roux (SLR) self-refocused pulse that addresses the limited specificity of conventional SPION imaging. METHODS: An adiabatic self-refocused RF pulse was designed using the SLR algorithm for frequency-selective positive-contrast imaging. The optimized pulse had a spectral bandwidth of 370 Hz, a peak RF amplitude of 13 μT, and a duration of 15 ms. FSI data were acquired on a 7T MRI scanner. Phantom experiments used agarose-embedded 30 nm cell-labeled SPION at 0%, 25%, 75%, and 100% concentrations (pure). In vivo validation was performed following intramuscular SPION injection into the hind limb of a mouse. FSI images were compared with conventional acquisitions. RESULTS: Quantitative phantom analysis showed normalized FSI signal intensities of 25.02% and 75.16% for samples containing 25% and 75% labeled cells, respectively, demonstrating an approximately proportional relationship between FSI signal and labeled-cell concentration. In vivo, FSI generated localized hyperintense positive contrast at the SPION injection site, providing improved conspicuity compared with the corresponding negative-contrast signal void. DISCUSSION AND CONCLUSION: FSI enables frequency-selective positive-contrast SPION imaging at 7T with improved robustness to B1 variations and a shorter calculated minimum echo time compared with the corresponding separate pulse-pair configuration. The self-refocused design may also offer potential advantages in RF power deposition, although SAR reduction remains to be quantitatively evaluated.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Frequency Shift Imaging Using an Adiabatic SLR Self-Refocused Pulse for Positive-Contrast SPION Imaging at 7T — Science Skim