Sensors (Basel, Switzerland)

Cane-Type Robots for Mobility Assistance-Design, Sensing, Control, and Fall Prevention: A Narrative Review.

José Luís Pereira, Miguel Armada, Rodolfo Cerqueira, Nuno Ferrete Ribeiro, Cristina P Santos

Center for MicroElectroMechanical Systems (CMEMS), University of Minho, 4800-058 Guimarães, Portugal.

Review

Key points

From the paper's conclusion
  • Conclusions: Cane-type robots show clear potential as mobility-assistance technologies, but the field remains constrained by limited clinical validation and by design choices that often increase sensing burden without demonstrating translational readiness.

Abstract

Introduction: Cane-type robots are emerging as a promising class of assistive devices for individuals with reduced mobility because they combine portability with the potential to improve stability, support gait, and contribute to fall detection and fall prevention. This review examines how these systems have been designed and validated, with particular emphasis on the trade-offs that may determine their real-world usefulness. Methods: This narrative review draws on 49 articles identified through a structured literature search from a pool of 2439 records remaining after duplicate removal. The included studies were examined through a narrative synthesis of structural design, sensing and actuation components, motion-control strategies, fall detection methods, fall-prevention approaches, and experimental validation. Data were coded at article level (N = 49) for experimental validation and at prototype level (N = 26) for design and functional characteristics. Unreported characteristics were retained as not reported and were not interpreted as absent. Results: Mobile bases provide up to 3 degrees of freedom (DOF), with additional DOFs enabled by revolute joints (1 DOF) and universal joints (2 DOFs). However, canes with one or two wheels often lack the stability required to support body weight safely during walking or fall events, which limits their suitability for the target population. All systems rely on cane-mounted sensors, whereas some also incorporate wearable sensors that may improve functionality but can reduce usability and long-term acceptability. Explicit gait-phase classification was documented in only 2/26 prototypes (7.7%); walking-state recognition, movement-intention estimation, foot-contact sensing, and fall-event detection were not counted as gait-phase detection unless discrete phases of the gait cycle were classified. Across the reviewed literature, the most important limitations are the scarcity of clinical gait trials involving older adults or mobility-impaired users and the very limited availability of active fall-prevention strategies that do not rely on wearable sensors. Conclusions: Cane-type robots show clear potential as mobility-assistance technologies, but the field remains constrained by limited clinical validation and by design choices that often increase sensing burden without demonstrating translational readiness. Future research should prioritize clinically validated prototypes, robust gait-phase recognition, and fall-prevention strategies based exclusively on cane-integrated sensing to improve reliability, usability, and real-world adoption.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Cane-Type Robots for Mobility Assistance-Design, Sensing, Control, and Fall Prevention: A Narrative Review — Science Skim