Smooth Subband Entropy and Time-Domain Feature Fusion for Personalized Lower-Limb Movement Recognition.
Jiang Chang, Zhengui Huang, Zhanfeng Ying, Fengrong Tang, Wenbo Chen, Chun Zheng, Zhihua Chen
National Key Laboratory of Transient Physics, Nanjing University of Science and Technology, No. 200 Xiaolingwei Street, Xuanwu District, Nanjing 210094, China. · School of Energy and Power Engineering, Nanjing University of Science and Technology, No. 200 Xiaolingwei Street, Xuanwu District, Nanjing 210094, China.
Key points
From the paper's conclusion- Across the evaluated amplitude-reference conditions, Fusion-XGB retained a macro-F1 improvement over TD-XGB, while absolute recognition performance varied with the reference definition.
Abstract
Surface electromyography (sEMG) supports personalized movement recognition, but feature utility must be interpreted together with preprocessing conditions. We evaluated a task-specific integration of a smooth fast Fourier transform (FFT) subband bank, nearest-neighbor entropy (NNE), time-domain (TD) descriptors, and participant-specific extreme gradient boosting (XGBoost). Nine-channel recordings from 40 Shenzhen Institute of Advanced Technology Lower Limb Motion Dataset (SIAT-LLMD) participants were evaluated for 16-class recognition using repetition-grouped five-fold cross-validation. Under complete-record amplitude normalization, the 216-dimensional fusion achieved 95.63% accuracy and 94.54% macro-F1, exceeding TD-XGB by 1.043 percentage points; random and repeated-feature expansion did not reproduce this gain. With the classifier configurations held fixed, macro-F1 was 94.85% with record-specific references fitted to all eligible samples, 95.58% with record-specific training-only references, and 75.31% with shared participant-level training references. The record-specific controls require movement-associated recording identity and do not establish prospective unknown-action performance. This gain was accompanied by median single-thread CPU computation of 34.210 ms per conditioned window for Fusion-XGB, compared with 5.392 ms for TD-XGB (approximately sixfold). Across the evaluated amplitude-reference conditions, Fusion-XGB retained a macro-F1 improvement over TD-XGB, while absolute recognition performance varied with the reference definition.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Nonlinear Feature Decomposition and Deep Temporal–Spatial Learning for Single-Channel sEMG-Based Lower Limb Motion RecognitionIEEE Sensors Journal · 2025
- Fusion of Nine-Channel sEMG and Dual-IMU Sensors for Knee-Angle Estimation Based on CatBoost Feature Selection and Neuron-Level Attention LSTMBiosensors · 2026
- An integrated wireless sEMG framework with Bayesian-optimized machine learning for multi-task locomotor classification and neuromuscular characterizationScientific Reports · 2026
- RTGNet: A Dual-Branch Network Integrating Recurrent Texture and Temporal Dynamics from sEMG for Lower-Limb Joint Angle Prediction.Sensors (Basel, Switzerland) · 2026
- Lower-Limb Kinematic Reconstruction from Surface Electromyography Across Locomotor Tasks Using Shared Muscle Synergies.Bioengineering (Basel, Switzerland) · 2026
- Lower Limb Motion Classification of Actions in Confined Environments Based on Multi-Source Signal Fusion and Muscle Symmetry Features.Sensors (Basel, Switzerland) · 2026