Validity Limits of High-Speed Laser-Speckle Modal Measurement on a Rotating Shaft: A Pre-Impact Falsification Test.
Jongyun Kim, Seongkeol Kim
Department of Mechanical Design and Robot Engineering, Seoul National University of Science and Technology, Seoul 01811, Republic of Korea. · School of Mechanical Systems Engineering, Seoul National University of Science and Technology, Seoul 01811, Republic of Korea.
Key points
From the paper's conclusion- Matched pre-impact comparisons provide an additional check, but passing this check does not confirm a structural mode.
Abstract
Laser-speckle tracking enables non-contact vibration measurement, but modal identification during rotation remains challenging. This study examines whether resonance-like frequency response functions and high coherence provide sufficient evidence of modal identification. A steel shaft was tested at 0, 100, and 200 rpm using impact excitation at four positions. The assessment combined stationary cross-validation against an accelerometer, matched pre-impact comparisons, and measurement of optical degradation. At 0 rpm, optical frequencies differed from contact-reference values by 1.06% at P2 and 2.60% at P3. The two rotating speeds and four excitation positions produced eight measurement conditions. Two yielded no candidate within the decision band. Six conditions yielded optical candidates. In three of these conditions, coherence at the selected frequency was higher before impact than after impact. Removing a linear phase trend eliminated one additional candidate; however, this outcome varied in leave-one-out tests. Two tracking methods produced candidates 12.21 Hz apart at 200 rpm, but the cause remained unresolved. Rotation increased the optical noise floor by 35-46 dB and reduced speckle correlation from 0.999 to 0.708. Under these conditions, high coherence alone did not validate modal identification. Matched pre-impact comparisons provide an additional check, but passing this check does not confirm a structural mode.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Geometry-Aware Fusion of Reflectance and Transmission Laser Speckle Contrast Imaging: In Vivo Agreement and Phantom-Defined Operating Limits.Journal of biophotonics · 2026
- Vibration-Based Measurement of Steel Wire Rope Fundamental Frequency Using an Optical Sensor: Mitigation of Mass-Loading Artifacts.Sensors (Basel, Switzerland) · 2026
- Global reset-speckle contrast optical spectroscopy.Biomedical optics express · 2026
- Micro-Displacement Measurement Based on Dual Optical Feedback Self-Mixing InterferencePhotonics · 2026
- Optimized Design of Laser Vibration Measurement Transceiver Optical System for Applications with Rough TargetsPhotonics · 2026
- Optical characterization of a laser speckle contrast imaging system for intraoperative blood flow monitoring.Biomedical optics express · 2026