Health-Margin-Aware Load Redistribution from Calibrated Sensor Evidence.
Anzuo Jiang, Hongkai Zhu, Heng Li, Wenhan Hou, Haoqiang Sun, Rui Huang
School of Computer and Control Engineering, Yantai University, Yantai 264005, China.
Key points
From the paper's conclusion- These results are limited to a numerical model and do not constitute physical, HIL, field, safety, or calibrated-capacity validation.
Abstract
Condition monitoring can identify abnormal operating states, but a diagnostic posterior does not specify how much load a remaining unit can accept after a dropout. We evaluate a sensor-to-action interface that converts calibrated condition probabilities into a bounded numerical recovery request using 1449 stable cycles from the UCI hydraulic-systems dataset. A four-way split is repeated for 10 seeds. Regularization is selected on validation; temperature, the lower-margin multiplier, the conformal threshold, and the quality-gate threshold are selected on calibration; the test fold is used once for final evaluation. Mean macro-F1 is 0.985 on clean cycles, 0.672 with 10% temporal-SD noise, and 0.766 after VS1 imputation. Relative to posterior-mean requests, the calibration-selected lower margin reduces request exceedance and modeled shortfall under all three inputs. Full recovery increases only under 10% noise (+0.0615); it is essentially unchanged under clean input (-0.0054, descriptive cluster interval -0.0212 to +0.0076) and lower after VS1 imputation (-0.0219, -0.0429 to -0.0019). A fixed κ=0.5 lower margin matches or modestly exceeds the calibration-selected margin in these matched numerical episodes, so calibration selection is not claimed to provide an additional action benefit. In condition-holdout tests under noise, family-level macro-F1 is 0.289-0.354; the worst held-out level is 0.177 and the lowest numerical recovery rate is 0.033. The quality gate abstains on all noisy holdout episodes. At q=0.95, an equal-z negative-control gate reduces automatic release from 0.583 to 0.333, with corresponding changes in conditional risk and recovery. Projection enforces the configured envelope, but map, envelope, and delay mismatch can produce true-envelope violations. These results are limited to a numerical model and do not constitute physical, HIL, field, safety, or calibrated-capacity validation.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluation of Machine-Learning-Guided Adaptive Sampling for Industrial Monitoring SystemsBig Data and Cognitive Computing · 2026
- The Power of Anomaly Detection in Predictive Maintenance: [Experiments & Analysis]Proceedings of the ACM on Management of Data · 2026
- Small-Sample Wear-Rate Prediction and a Conditional-Quantile-Informed Maintenance Decision Interface for High-Speed Train Brake Pads Using Sparse Life-Cycle RecordsLubricants · 2026
- Attention-Based Quantile Regression for RUL Uncertainty Prediction.Sensors (Basel, Switzerland) · 2026
- Measurement Uncertainty and Deep Learning for Reliability Estimation: A Mission-Profile-Based Framework for Power Electronic SystemsSensors · 2026
- Auditing Decision Stability After Missing Data Repair with Split Conformal BoundsQuality and Reliability Engineering International · 2026