Electrochemical Sensing of Estradiol Using an Fe3O4/fMWCNT-Modified Carbon Paste Electrode.
Ana Đurović, Zorica Stojanović, Sanja Panić, Marija Milanović, Snežana Kravić, Lukáš Richtera
Faculty of Technology Novi Sad, University of Novi Sad, Bul. cara Lazara 1, 21102 Novi Sad, Serbia. · Department of Chemistry and Biochemistry, Mendel University in Brno, Zemědělská 1, 613 00 Brno, Czech Republic.
Key points
From the paper's conclusion- A sensitive and reproducible electroanalytical method was developed for the selective determination of estrogen hormone estradiol (EST) using a carbon paste electrode (CPE) modified with Fe3O4-functionalized multi-walled carbon nanotubes (Fe3O4/fMWCNTs-CPE).
Abstract
A sensitive and reproducible electroanalytical method was developed for the selective determination of estrogen hormone estradiol (EST) using a carbon paste electrode (CPE) modified with Fe3O4-functionalized multi-walled carbon nanotubes (Fe3O4/fMWCNTs-CPE). The Fe3O4/fMWCNT composite was synthesized via wet impregnation and characterized by field-emission scanning electron microscopy, energy-dispersive X-ray spectroscopy, and X-ray diffraction, while the sensor's electrochemical and interfacial properties were assessed using cyclic voltammetry and electrochemical impedance spectroscopy. Electrochemical studies revealed an irreversible oxidation peak for EST, and square-wave voltammetry was optimized for its determination in 0.1 mol/L phosphate buffer (pH 5.0). Under optimal conditions, the sensor exhibited a linear dynamic range (up to 20 µM) with a detection limit of 21.5 nM, indicating high sensitivity. Moreover, it showed good selectivity in the presence of common interfering substances. The method was successfully applied for EST determination in one urine sample, one water sample, and one pharmaceutical tablet sample, achieving high recovery values (98.53-101.79%), with RSD values below 2.40%, requiring only sample dilution without additional pretreatment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Molecularly imprinted electrochemical sensor for sensitive determination of 17β-estradiol in real water samples.Talanta · 2026
- A 2D Iridium/Graphitic Carbon Nitride Nanosheet Electrochemical Sensor for 17β‐Estradiol DeterminationAnalysis & Sensing · 2026
- Adsorption-regulated electrochemical determination of 17α-ethinylestradiol based on a Cu@Fe2O3 composite-modified electrode.Talanta · 2026
- Non-enzymatic square-wave voltammetric determination of progesterone using an MWCNT-IMZ composite.Clinica chimica acta; international journal of clinical chemistry · 2026
- Molecularly Imprinted Polymer/Cu@g‐ C 3 N 4 Nanocomposite‐Based Biomimetic Sensor for Capacitive Detection of 17β‐Estradiol in Human SalivaJournal of Applied Polymer Science · 2026
- Nanoconfinement-Driven Solid-State Ratiometric Fluorescent Aptasensor for 17β-Estradiol Detection in Complex Matrices.Biosensors · 2026