Sensors (Basel, Switzerland)

Sensor-Based Assessment of Trunk-Lower Limb Neuromuscular Coordination During Flat Tennis Serve Using Surface Electromyography and Time-Frequency Intermuscular Coherence Analysis.

Yifei Jiang, Weihao Jiang

School of Physical Education, Hangzhou Normal University, Hangzhou 311121, China.

Observational

Key points

From the paper's conclusion
  • Integrated electromyography (IEMG) was normalized to maximal voluntary contraction, and time–frequency intermuscular coherence was calculated for 21 trunk–lower limb muscle pairs across the α, β, and γ frequency bands.

Abstract

OBJECTIVE: To compare flat-serve performance, muscle activation, and trunk-lower limb time-frequency intermuscular coherence between professional and amateur tennis players. METHODS: Twenty-four tennis players (17 male and 7 female), including 12 professional and 12 amateur players, participated in this cross-sectional group-comparison study. Each participant completed 10 valid flat serves under standardized testing conditions, and serve-placement accuracy was assessed using a predefined target area. Surface electromyographic signals from 10 dominant-side trunk and lower-limb muscles were recorded using a Delsys Trigno Wireless EMG System, while serve movements were captured using a Photron FASTCAM Mini AX200 high-speed camera. Electromyographic and video data were synchronized using a transistor-transistor logic trigger. Integrated electromyography (IEMG) was normalized to maximal voluntary contraction, and time-frequency intermuscular coherence was calculated for 21 trunk-lower limb muscle pairs across the α, β, and γ frequency bands. Between-group differences were examined using two-tailed independent-samples t-tests. The Benjamini-Hochberg false discovery rate (BH-FDR) procedure was applied to outcome families involving multiple comparisons, with statistical significance determined at FDR q < 0.05. RESULTS: Serve-placement accuracy was significantly higher in the professional group than in the amateur group (69.2 ± 7.4% vs. 48.3 ± 8.9%; t = 6.26, raw p < 0.001, Cohen's d = 2.55). After BH-FDR correction, professional players showed significantly higher IEMG values in the soleus (t = 3.12, raw p = 0.005, FDR q = 0.019, d = 1.27), vastus medialis (t = 2.92, raw p = 0.008, FDR q = 0.020, d = 1.19), vastus lateralis (t = 2.60, raw p = 0.016, FDR q = 0.027, d = 1.06), gluteus maximus (t = 3.17, raw p = 0.004, FDR q = 0.019, d = 1.29), and latissimus dorsi (t = 2.74, raw p = 0.012, FDR q = 0.024, d = 1.12), but significantly lower IEMG in the rectus abdominis (t = -3.07, raw p = 0.006, FDR q = 0.019, d = -1.25). Several muscle pair-frequency combinations showed nominal differences based on raw p-values and moderate-to-large effect sizes; however, none of the time-frequency intermuscular coherence comparisons remained statistically significant after BH-FDR correction (all FDR q > 0.05). CONCLUSION: Professional players demonstrated greater flat-serve placement accuracy and a distinct distribution of trunk and lower-limb muscle activation. The coherence findings were exploratory and did not conclusively establish skill-level differences in trunk-lower limb intermuscular coupling. Flat-serve training may emphasize lower-limb support and propulsion, hip extension, and trunk stabilization rather than focusing exclusively on arm or racket actions.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Sensor-Based Assessment of Trunk-Lower Limb Neuromuscular Coordination During Flat Tennis Serve Using Surface Electromyography and Time-Frequency Intermuscular Coherence Analysis — Science Skim