Assessing Observable Resolution in Open-Access sEMG Datasets for High-Resolution Hand-Gesture Research: A Quantization-Aware Methodological Study.
Alexandra Gomez-Caraveo, Miguel E Bravo-Zanoguera, José A Amezquita-García, Guillermo Galaviz, Fabian N Murrieta-Rico
Facultad de Ingeniería, Universidad Autónoma de Baja California, Mexicali 21100, Baja California, Mexico. · Ingeniería Mecatrónica, Universidad Politécnica de Baja California, Mexicali 21376, Baja California, Mexico.
Key points
From the paper's conclusion- The results show that nominal analog-to-digital converter (ADC) resolution and stored numerical precision alone cannot establish acquisition-level quantization integrity.
Abstract
Open-access surface electromyography (sEMG) datasets are widely used for gesture-recognition research; however, limited documentation of acquisition and post-processing may prevent verification of whether the numerical structure imposed during acquisition is preserved in the distributed data. This study evaluates one selected signal vector from each of eleven public forearm sEMG datasets using a quantization-aware framework, complemented by an assessment across participants and channels to examine within-dataset consistency. The framework distinguishes declared resolution (DR) from observable effective resolution (OER), a signal-dependent descriptor of the numerical granularity observable in the distributed data rather than a measure of hardware ENOB. The analysis uses the minimum nonzero first-order difference (Δmin), zero-difference proportion (P0), relative signal cardinality, and a quantization-grid alignment metric (Egrid) to characterize numerical discreteness and grid preservation. Recordings analyzed from five datasets exhibited ordered difference levels consistent with a preserved observable quantization grid, whereas those from six showed disrupted structures. The complementary assessment revealed both consistent numerical patterns and within-dataset variability across the examined recordings. Egrid quantified approximate grid alignment at the adopted tolerance, while P0 and cardinality served as complementary descriptors. Validation using an independently documented 24-bit dataset yielded Egrid = 1, despite low P0 and high cardinality, demonstrating that these indirect descriptors depend on signal and acquisition characteristics. The results show that nominal analog-to-digital converter (ADC) resolution and stored numerical precision alone cannot establish acquisition-level quantization integrity. Numerical auditing can therefore provide additional traceability when public datasets are used to investigate signal resolution and quantization effects.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Electrode-Level Low-Dimensionality Does Not Guarantee Sensor Redundancy: Dual-Dataset, Participant-Grouped Validation of Parsimonious Myoelectric Gesture Decoding.Biomimetics (Basel, Switzerland) · 2026
- A Scalable and Efficient Hardware Accelerator for Realtime EMG-based Gesture Recognition using Deep LearningCurrent Directions in Biomedical Engineering · 2026
- Systematic Evaluation of sEMG Processing Pipelines for Gesture Recognition.Bioengineering (Basel, Switzerland) · 2026
- Real-time gesture classification via spike trains and multi-scale temporal features from sEMG signalsScientific Reports · 2026
- A Dataset of Electromyographic Signals for Developing Hand Gesture Recognition SystemsScientific Data · 2026
- Uncertainty-Aware Single-Channel Surface EMG Classification for Low-Resource Hand Gesture Recognition: A Subject-Independent EvaluationMedical & Biological Engineering & Computing · 2026