Cobalt Single-Atom/Nanoparticle Dual Sites on Unzipped Carbon Nanotubes for Electrolyte-Switchable Glucose and Uric Acid Sensing.
Alfi Rodiansyah, Changhyun Do, Sae Yane Paek, Jong Min Kim, Joonwon Lim
Department of Information Display, College of Sciences, Kyung Hee University, Seoul 02447, Republic of Korea. · Laboratoire de Physique de la Matière Condensée, CNRS, École Polytechnique, Institut Polytechnique de Paris, 91128 Palaiseau, France.
Key points
From the paper's conclusion- Here, we report an electrolyte-regulated bifunctional electrocatalyst comprising atomically dispersed Co-N/O sites and Co/CoO nanoparticles anchored on nitrogen-doped unzipped carbon nanotubes (SA/NP Co@N-UzCNT) for selective glucose and uric acid (UA) detection.
Abstract
Non-enzymatic multi-analyte sensing using a single electrode remains challenging owing to the distinct electrochemical environments and catalytic pathways required for different biomarkers. Here, we report an electrolyte-regulated bifunctional electrocatalyst comprising atomically dispersed Co-N/O sites and Co/CoO nanoparticles anchored on nitrogen-doped unzipped carbon nanotubes (SA/NP Co@N-UzCNT) for selective glucose and uric acid (UA) detection. Partial unzipping of the outer CNT walls generates edge-rich graphene nanoribbons while preserving the electrically conductive inner CNT framework, providing abundant N-coordination sites for stabilizing structurally distinct Co motifs. Under alkaline conditions, nanoparticle-derived Co sites are electrochemically converted into catalytically active CoOOH species that promote glucose oxidation, whereas atomically dispersed Co-N sites dominate UA oxidation under neutral conditions, demonstrating electrolyte-dependent catalytic selectivity between the two Co configurations. Switching the electrolyte environment alters the dominant catalytic site, enabling selective detection of glucose and UA using a single-electrode architecture. The resulting sensor achieves sensitivities of 65.18 µA mM-1 cm-2 for glucose in the concentration range of 1-8 mM and 337.5 µA mM-1 cm-2 within the concentration range of 5-500 µM for UA. Practical applicability is demonstrated using a screen-printed electrode strip, which retains approximately 89% of its initial glucose response after 15 days. This work demonstrates that single-atom/nanoparticle coexistence can serve as a functional catalytic architecture for electrolyte-regulated non-enzymatic multi-analyte sensing.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Carbon-coated CoNiFeCuCr high-entropy alloy nanoparticles for robust electrochemical simultaneous detection of dopamine and uric acid.Talanta · 2026
- Light- and H2O2-Switchable Dual-Enzyme Carbon Dot Nanozymes with Fe-Pyrrolic N Dual Sites for Orthogonally Activated Multimodal Detection of Glutathione and Hydrogen Peroxide.Analytical chemistry · 2026
- Ce and Ni Supported on N-Doped Carbon as a Diatomic Nanozyme and a Colorimetric Sensor for the Detection of ArseniteACS Applied Nano Materials · 2026
- Synergistic Fe/Ni single-atom N-doped carbon nanotubes functionalized paper microfluidic chip for on-site simultaneous determination of nitrofurantoin and chloramphenicol.Talanta · 2026
- Single-atom catalysts for electrochemical sensing of dopamine, uric acid, and ascorbic acid: from active-site structure to sensing performance.Chemical communications (Cambridge, England) · 2026
- Modular Electrochemical Sensing via In Situ Reduced Carbon Quantum Dot-Nanotube Molecular Hybrids.ACS applied materials & interfaces · 2026