A Hybrid Optical-Neural Network Approach for Micro-Vibration Image Shift Estimation in Space Cameras.
Minlong Lian, Dawei Sang, Pu Wang, Xin Yi
School of Mechanics and Engineering Science, Peking University, Beijing 100871, China.
Key points
From the paper's conclusion- High-resolution space cameras require continuous knowledge of micro-vibration-induced image shift for image quality assessment and potential future compensation.
Abstract
High-resolution space cameras require continuous knowledge of micro-vibration-induced image shift for image quality assessment and potential future compensation. This paper presents a simulation-based feasibility study of an optical measurement-assisted neural regression method that estimates imaging channel image shift without re-solving a full finite element model during inference. A high-frame-rate measurement channel shares the primary optics with the imaging channel; a lightweight, INT8-quantized and structurally pruned conventional neural regressor estimates the observable correction formed by the two measurement branch mirrors from rendered measurement frames, a calibrated sensitivity relation converts synchronized mirror-6 angular metrology into the same units, and both are added to the tracked measurement channel displacement. On the simulated dual-channel dataset, the proposed estimator reduces the correction RMSE from 0.396 px (centroid-only tracking) and 0.236 px (a specified structural-mismatch surrogate) to 0.130 px (0.133 px after INT8 quantization), which coincides with the structural scale of 0.132 px set by the common-path compensation residual; the remaining end-to-end image shift error of 0.398 px is dominated by the 0.378 px displacement tracking term rather than by the regressor. Its reported 0.0150 ms figure is a compute-only throughput estimate based on an assumed 120 GOPS INT8 accelerator; it excludes sensor exposure and readout, data transfer, synchronization, centroid tracking, and other pipeline overheads. A compute-only estimate does not establish the achievable end-to-end frame rate. The analytical error budget decomposes the measured shift error into displacement tracking, auxiliary metrology, and correction-scale terms and reproduces the measured value to within 1%. The modeled measurement branch does not observe independent motion of the imaging-only mirror; auxiliary state information or a validated mechanical constraint is required for a physically realizable estimator. The reported synthetic accuracy does not establish this observability; independent ray-tracing validation, optical bench experiments, hardware-in-the-loop tests, edge-hardware profiling, and on-orbit validation have not been performed.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Exposure-Adaptive Optimization of Star Cameras under Exposure Disturbances: A Surrogate Model-Based DDPG ApproachJournal of Physics: Conference Series · 2026
- Neural aberration fields: continuous implicit representation of spatially varying point spread functions for vision simulation.Journal of the Optical Society of America. A, Optics, image science, and vision · 2026
- Highly scalable machine vision enabled with meta-optics-based ultra-wide neural networkeLight · 2026
- Limits and trade-offs of shift-invariant meta-optical encoders for image compression.Optics letters · 2026
- Physics-Preserving Attention-Guided Artifact Removal for Spaceborne Optical Images.Journal of imaging · 2026
- Noise-robust optical convolutional neural networks with learnable bit-plane weighted fusion.Optics letters · 2026