From the paper's conclusion
  • This study proposes a radar-performance-oriented spectral operator for FMCW radar velocity measurement and incorporates it, together with vibration PSD and higher-order statistical features, into the reconstruction process.

Abstract

Tracked vehicles operating under off-road conditions subject onboard frequency-modulated continuous-wave (FMCW) radars to broadband and impulsive vibration, making vibration-environment reconstruction important for repeatable laboratory evaluation of vibration-induced sensing degradation. Conventional reconstruction methods mainly target vibration-signal characteristics, such as power spectral density (PSD), root mean square (RMS), and higher-order statistics, without explicitly accounting for the frequency-selective influence of vibration components through the radar processing chain. This study proposes a radar-performance-oriented spectral operator for FMCW radar velocity measurement and incorporates it, together with vibration PSD and higher-order statistical features, into the reconstruction process. Numerical simulations assess reconstruction performance, and shaker tests assess laboratory implementation and consistency with a model-based radar reference. Compared with reconstruction based on PSD and higher-order statistics, the proposed method reduces the mean relative L2 error of the sensitive-band effective-energy vector from 38.07% to 16.95%. In simulation, the reconstructed main-peak broadening and spurious-peak center position are 1.26m/s and 0.68m/s, corresponding to relative errors of 4.13% and 1.45%, respectively, with respect to the simulated original-vibration response. In shaker tests, the corresponding measured values are 1.133m/s and 0.637m/s, with relative deviations of 6.36% and 7.68%, respectively, from the simulation reference obtained using the original measured vibration input. The results support improved agreement with the model-based reference in the evaluated cases while maintaining comparable vibration statistical characteristics. Accuracy relative to actual field radar degradation remains unverified because an independent field-measured radar baseline is unavailable.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Vibration Environment Reconstruction for FMCW Radar Using a Radar-Performance-Oriented Spectral Operator — Science Skim