Sensors (Basel, Switzerland)

An Adaptive State- and Morphology-Based Four-Event Segmentation Algorithm for Sit-to-Stand-to-Sit Cycles from Wii Balance Board Load Signals: An Exploratory Comparison with Noraxon Report-Consistent IMU Timing.

Xiaoliang Qiu, Yinghong Liu, Dae-Sung Park

Department of Physical Therapy, Konyang University, 158 Gwanjeodong-ro, Seo-gu, Daejeon 35365, Republic of Korea.

Computational

Key points

From the paper's conclusion
  • We developed an adaptive state- and morphology-based algorithm that identified ten internal anchors in Wii Balance Board (WBB) vertical-load waveforms and derived an ordered P1–P4 chain representing cycle start, end of sit-to-stand, start of stand-to-sit, and cycle end, respectively.

Abstract

Sit-to-stand (STS) tests are often summarized by completion time or repetition count; however, phase-specific analysis requires reproducible operational segmentation. We developed an adaptive state- and morphology-based algorithm that identified ten internal anchors in Wii Balance Board (WBB) vertical-load waveforms and derived an ordered P1-P4 chain representing cycle start, end of sit-to-stand, start of stand-to-sit, and cycle end, respectively. The algorithm was developed using 108 T1-T3 trials and then applied unchanged to a temporally separate batch of 24 T0 trials. Fourteen T0 participants overlapped with development and 10 were included in a descriptive subset of participants not represented in the development dataset. Complete chains were identified in 24/24 T0 trials and 10/10 descriptive-subset trials (100%; exact 95% CI, 69.2%-100%), versus 7/24 for the prespecified internal non-adaptive baseline. Complete-chain identification remained 100% across all three datasets under one-at-a-time perturbations of ±10% and ±20% of 52 frozen numerical parameters, although selected sit-down rules shifted local boundaries. Removing the separate seated-baseline/fallback component reduced complete-chain identification to 101/108, 12/24, and 8/10. Across 131 paired trials, WBB total-cycle duration differed from Noraxon software (MR 4.2.34 Software; Noraxon, Scottsdale, AZ, USA)-reported duration by -0.188 s (95% CI, -0.313 to -0.060). These differences reflect distinct operational timing definitions rather than error against an independent reference standard. Independent reference-event and external clinical studies remain necessary.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

An Adaptive State- and Morphology-Based Four-Event Segmentation Algorithm for Sit-to-Stand-to-Sit Cycles from Wii Balance Board Load Signals: An Exploratory Comparison with Noraxon Report-Consistent IMU Timing — Science Skim