Standardized Short-Wave Infrared Hyperspectral Imaging for Non-Destructive Spectral Comparison of Coin Denominations, Design Variants, and Surface-Use Conditions.
Hsin-Che Wang, Kuo-Chih Su, Yi-Jing Sheen, Chiu-Chin Sung, Min-Yi Chou, Kuan-Jung Pan, Hsian-Min Chen
Center for Quantitative Imaging in Medicine (CQUIM), Department of Medical Research, Taichung Veterans General Hospital, Taichung 407219, Taiwan. · Department of Medical Research, Taichung Veterans General Hospital, Taichung 407219, Taiwan.
Key points
From the paper's conclusion- This study established a standardized 900–1700 nm short-wave infrared hyperspectral imaging (SWIR-HSI) workflow for controlled and non-destructive spectral comparison of metallic coins.
Abstract
Coins contain multiple types of information, including denomination, design variant, year of issue, and surface condition. This study established a standardized 900-1700 nm short-wave infrared hyperspectral imaging (SWIR-HSI) workflow for controlled and non-destructive spectral comparison of metallic coins. Twenty-five independent New Taiwan dollar (NT$10) coins were used to evaluate imaging position, coin side, and aperture setting. At position 13 on the reverse side, the mean spectral standard deviations were 0.192, 0.142, and 0.151 for F1.8, F2.8, and F4, respectively, and F2.8 was selected for subsequent measurements. Using the same NT$10 coin, support-material and in-plane rotation experiments produced spectral angle mapper (SAM) ranges of 0.232-1.087 and 0.132-0.581, respectively. Under the standardized conditions, the SAM value between one new and one circulated NT$10 coin was 0.729. Pairwise SAM values ranged from 0.260 to 1.680 among eight NT$10 design variants and from 0.458 to 2.449 among six denomination or special-year samples. An initial repeatability evaluation under the current experimental conditions, using three additional NT$10 coins and 24 acquisitions, yielded mean SAM values of 0.2450°, 0.6368°, and 0.3323° for repositioning, inter-day, and inter-operator comparisons, respectively, with an overall median spectral CV of 0.83%. These results quantitatively demonstrate that acquisition conditions affect SWIR spectral measurement and that selected coin samples exhibit measurable spectral differences under controlled conditions. The present study focuses on acquisition standardization and descriptive spectral comparison and does not establish validated coin classification, material identification, or surface-condition assessment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Near-Infrared Hyperspectral Imaging for Non-Destructive Detection of Old Rice in Freshly Milled Rice.Foods (Basel, Switzerland) · 2026
- Advances in Hyperspectral Imaging for Nondestructive Food Quality and Safety DetectionFoods · 2026
- High-Throughput eSWIR Hyperspectral Imaging for Pharmaceutical Classification at Industrial Line Speeds.AAPS PharmSciTech · 2026
- Review of advances in hyper-spectral imaging-based non-destructive testing methods in food applicationJournal of Food Composition and Analysis · 2026
- High-throughput pharmaceutical classification via short-range interferometric hyperspectral imaging.Talanta · 2026
- An AI-Assisted Workflow for Tea Product Discrimination and Moisture Prediction Using Portable NIR Spectroscopy.Foods (Basel, Switzerland) · 2026