Reliability of Markerless 2D Video Analysis for Calculating Gait Joint Angles in Uncontrolled Environments.
Sagrario Pérez-de la Cruz, Francisco Molina-Rueda, Pilar Fernández-González
Department of Nursery, Physiotherapy and Medicine, University of Almería, 04120 Almería, Spain. · Department of Physical Therapy, Occupational Therapy, Rehabilitation and Physical Medicine, Faculty of Health Sciences, Rey Juan Carlos University, 28922 Madrid, Spain.
Key points
From the paper's conclusion- Background: Traditional 3D gait analysis constrains natural movement variability due to artificial laboratory settings; thus, this study evaluated the intra- and inter-rater reliability of a low-cost, 2D markerless smartphone video protocol for assessing lower limb sagittal kinematics in an unconstrained environment.
Abstract
Background: Traditional 3D gait analysis constrains natural movement variability due to artificial laboratory settings; thus, this study evaluated the intra- and inter-rater reliability of a low-cost, 2D markerless smartphone video protocol for assessing lower limb sagittal kinematics in an unconstrained environment. Methods: Forty-five healthy young adults walked at a self-selected speed in a non-laboratory corridor, where sagittal hip, knee, and ankle angles were recorded at 60 fps and analyzed using Kinovea® software by two independent raters, with one rater repeating measurements seven days later. Results: Inter-rater reliability ranged from moderate to good across most joint variables (ICC = 0.628-0.789), except for the ankle during loading response, which showed poor consistency (ICC = 0.381). Between-session intra-rater reliability was generally lower, ranging from poor to moderate (ICC = 0.278-0.580), with the lowest values observed at the hip (ICC = 0.278) and ankle (ICC = 0.391) during loading response. Minimal Detectable Change (MDC95) values ranged from 7.07° to 8.95° for inter-rater assessments and from 7.40° to 16.55° for intra-rater assessments, with Bland-Altman analysis displaying wide limits of agreement longitudinally. Conclusions: In conclusion, while prior observer training standardizes criteria for immediate cross-sectional evaluations, the protocol's high sensitivity to measurement variability and unconstrained motor execution limits its clinical application for longitudinal tracking across different sessions. Between-session intra-rater variability reflects evaluator subjectivity in manual frame selection and landmark digitization over time when no physical markers are present, rather than biological gait fluctuations.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Evaluating the Agreement of Markerless Motion Capture for Joint Angle Estimation in a Constrained Hallway Setting Compared With a Traditional Laboratory SettingJournal of Applied Biomechanics · 2026
- Individual step and participant mean validation of Gaitly's smartphone video-based gait analysis system.Frontiers in rehabilitation sciences · 2026
- Gait assessment using a 2D video-based pose estimation app in comparison to a markerless motion capture system in subjects with osteoarthritis of the knee - a pilot study.Frontiers in bioengineering and biotechnology · 2026
- From linear to nonlinear gait measures: validity of a multi-view markerless motion capture systembioRxiv · 2026
- AI-driven correction of video-derived gait kinematics in healthy older adults.IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2026
- Effect of Walking Speed on the Reliability of a Smartphone-Based Markerless Gait Analysis SystemSensors · 2025