Methodological Framework for Multi-Cell Posturography Enabling Unconstrained Foot Placement and Open-Source Balance Assessment.
Otto Hofstätter, Thomas Bochdansky, Anton Sabo, Mikael Bäckström
Engineering, Mathematics and Science Education, Mid Sweden University, SE-831 25 Östersund, Sweden. · Life Science Engineering, University of Applied Sciences Technikum Wien, A-1200 Vienna, Austria.
Key points
From the paper's conclusion- The platform dimensions (355 × 460 mm) and sensor topography geometrically accommodate natural external foot rotation (incorporating a 10° toe-out angle projection) and foot lengths corresponding to EU shoe sizes up to 55.
Abstract
BACKGROUND/OBJECTIVES: Computer-assisted posturography is utilized to quantify human postural control, yet existing dedicated systems frequently present physical constraints, such as limited sensing surfaces and rigid hardware barriers. In this study, a methodological framework is presented and a structural arrangement (OpenBalance) is designed to implement balance assessment accommodating a wider anthropometric range through zone-based foot placement using a decentralized load cell array, with preliminary implementation details provided in a repository. METHODS: The configuration comprises an array of 16 discrete uniaxial vertical-force load cells embedded within four mechanically decoupled sub-platforms to minimize mechanical cross-talk. Biomechanical moment equations were implemented in a custom Python pipeline to compute a localized Center of Pressure (COP) for each sub-platform independently. A vector-based data fusion algorithm maps these local coordinates into a unified global coordinate system. The system evaluation incorporated baseline signal-to-noise ratio (SNR) analysis, mechanical crosstalk testing, and digital low-pass filtering. RESULTS: A proof-of-concept evaluation using empirical data confirmed that the cascading coordinate model produces a continuous global COP trajectory and quadrant-specific load distributions. The platform dimensions (355 × 460 mm) and sensor topography geometrically accommodate natural external foot rotation (incorporating a 10° toe-out angle projection) and foot lengths corresponding to EU shoe sizes up to 55. Mechanical crosstalk between adjacent sub-platforms remained minimal (<1% of applied load). CONCLUSIONS: The OpenBalance framework confirms the technical feasibility of deriving a continuous global COP from a decentralized array of distributed load cells. While baseline component specifications and static verifications are established, comprehensive dynamic cross-validation against reference standards remains a necessary next step for the future development of open hardware that can be produced using 3D printing.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- OpenBalance: An Interoperable Computational Framework, Progressive 8-Stage Protocol, and Outlier Metric for Dynamic Posturography—A Technical Proof-of-ConceptComputers · 2026
- Machine learning-based multi-domain model for SOT composite score prediction using quiet standing COP data.Biomedical engineering letters · 2026
- A Composite Biomechanical Index for Dynamic Postural Control in Canadian Canoe AthletesInternational Journal of Sports Medicine · 2026
- Standardization and optimization of force platform testing for balance assessment in cervical spondylotic myelopathy.Frontiers in neuroscience · 2026
- Axis-dependent relationships and agreement between whole-body and limb-specific center of pressure measurements in dogs.Frontiers in veterinary science · 2026
- Spatial Decoupling of Foot-Substrate Cross-Talk in Plantar Pressure Sensor Arrays.Biomimetics (Basel, Switzerland) · 2026