Wearable Multi-Sensor Fusion for Field Assessment of Dynamic Postural Stability During the Curling Delivery in Young Adult Curlers: Integrating Trunk Kinematics, Plantar Pressure and Core-Muscle Activation.
Bowen Zhang, Jiying Wu, Tianhao Han, Jian Zhang, Daqi Jiang
Department of Physical Education, Northeastern University, Shenyang 110819, China. · School of Management and Journalism Communication, Shenyang Sport University, Shenyang 110819, China.
Key points
From the paper's conclusion- This study developed and validated a wearable multi-sensor system that fuses trunk and pelvis inertial measurement units (IMUs), instrumented plantar-pressure insoles and core-muscle surface electromyography (sEMG) to quantify dynamic postural stability during the simulated curling delivery in 110 young adult curlers (age range 18-24 years).
Abstract
Postural control in curling is expressed during a dynamic, sport-specific delivery on a single sliding leg, yet it is still assessed almost exclusively with static single-leg force-plate protocols that poorly reflect on-ice demands. This study developed and validated a wearable multi-sensor system that fuses trunk and pelvis inertial measurement units (IMUs), instrumented plantar-pressure insoles and core-muscle surface electromyography (sEMG) to quantify dynamic postural stability during the simulated curling delivery in 110 young adult curlers (age range 18-24 years). A four-phase segmentation of the delivery was implemented, and a compact 28-feature set was extracted and combined through a complementary Kalman fusion scheme into a single Dynamic Stability Index (DSI). Validated against a reference force plate during static single-leg standing, the IMU-derived sway path showed a small bias (~0.4 cm) with 95% limits of agreement of approximately +4.4 to -3.6 cm, and between-day reliability of the fused DSI was excellent (ICC(3,1) = 0.90, 95% CI [0.82, 0.95]). A random-forest classifier discriminated high- from low-stability deliveries with 91.8% accuracy (95% CI [87.2%, 95.1%]; AUC = 0.92, 95% CI [0.87, 0.96]), outperforming any single-sensor or static force-plate baseline. Sensor-derived dynamic metrics correlated with external-oblique strength, trunk proprioceptive error and motor self-efficacy (Spearman ρ ranging from -0.55 to 0.51, all p < 0.001 after Holm-Bonferroni correction), and dynamic instability increased monotonically across descending self-efficacy tertiles. The proposed system provides a portable, context-relevant and interpretable tool for balance profiling in young curlers, and demonstrates that multi-sensor fusion substantially improves measurement fidelity over conventional single-modality assessment.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Inertial Sensor Reliability and Validity Across a Five-Level Surface Instability Gradation During Single-Leg StandingSensors · 2026
- Reliability and Validity of Lumbar-Mounted IMU for Postural Sway Assessment in Healthy Adults.Sensors (Basel, Switzerland) · 2026
- Sensor Fusion Pipeline for Gait Analysis Using Insole-Embedded Inertial Measurement Units (IMUs).Sensors (Basel, Switzerland) · 2026
- Wearable sensors and artificial intelligence for proprioceptive assessment and rehabilitation after sports injuries: a narrative reviewFrontiers in Bioengineering and Biotechnology · 2026
- Concurrent Validity and Between-System Agreement of a Commercial Wearable Inertial Sensor System for Gait and Postural Sway Assessment in Progressive Supranuclear Palsy.Sensors (Basel, Switzerland) · 2026
- IMU-based gait analysis methods: a systematic review of techniques for different body locationsFrontiers in Sports and Active Living · 2026