A Proposal for an Ultrasensitive Label-Free Optical BioMEMS Platform Based on a DBR-Michelson Interferometer for Cancer Detection and Therapeutic Applications.
Bocar Ndiaye, Naima Brahiti, Kazem Nouri, Taha Azad, Kian Jafari
Interdisciplinary Institute for Technological Innovation (3IT), Faculty of Engineering, Université de Sherbrooke, Sherbrooke, QC J1K 0A5, Canada. · Department of Pathology and Laboratory Medicine, Faculty of Medicine, University of British Columbia, Vancouver, BC V6T 2B5, Canada.
Key points
From the paper's conclusion- Numerical simulations using COMSOL Multiphysics demonstrate a narrow full width at half maximum (FWHM) of 27.6 nm, a quality factor (Q) of 53.34, and an overall sensitivity of 75.74 µm/(N/m).
Abstract
Early detection of cancer remains challenging due to the extremely low concentration of biomarkers present during initial disease stages. Dysregulation of key signaling pathways, including cyclin-dependent kinase (CDK) networks, drives uncontrolled cell proliferation and tumor progression, underscoring the need for highly sensitive, label-free biosensing technologies. Conventional analytical methods such as ELISA and PCR offer reliable detection but require complex sample preparation, fluorescent labeling, and long processing times, limiting their suitability for rapid diagnostics. This work introduces a novel label-free Biological Micro-Opto-Electro-Mechanical System (BioMEMS) platform based on an unbalanced Michelson interferometer with DBR mirrors to interrogate the minute spectral shifts induced by biomolecular interactions. A microcantilever is suspended above a silicon-on-insulator (SOI) waveguide, where the specific binding of biomarkers generates compressive surface stress, causing a downward deflection that reduces the cantilever-to-waveguide gap. This displacement modulates the effective refractive index of the sensing arm through enhanced evanescent-field coupling. The resulting phase variation is further detected through the high-sensitivity Michelson interferometric architecture, enabling ultrasensitive spectral interrogation. Numerical simulations using COMSOL Multiphysics demonstrate a narrow full width at half maximum (FWHM) of 27.6 nm, a quality factor (Q) of 53.34, and an overall sensitivity of 75.74 µm/(N/m). These results highlight the potential of the proposed platform for early cancer detection and precise monitoring of dysregulated signaling pathways.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Surface Plasmon Resonance Analysis of Cancer‐Related Refractive Index Variations Using a MoTe₂ –Black Phosphorus–Cu Multilayer StructureSurface and Interface Analysis · 2026
- Label-Free Refractive-Index-Based Detection of Breast, Leukemia, and Prostate Cancer Cells Using a Tetra-Core PCF SPR Biosensor.Biosensors · 2026
- Performance Optimization of a Kretschmann‐Configured Multilayer MgO/Ag/HfO 2 /2D‐WS 2 SPR Biosensor for Refractive Index‐Based Cancer Cell Detection: A TMM and FEM ApproachAdvanced Theory and Simulations · 2026
- Design and Simulation of Multilayer SPR Biosensor Based on BK7/Ag/BN/BlueP/WSe 2 /BP for Label‐Free Detection of A549 Lung Cancer CellsAdvanced Theory and Simulations · 2026
- Optical biosensors for cancer diagnosis and monitoring.Clinica chimica acta; international journal of clinical chemistry · 2026
- Gold-Coated Extrinsic Semi-Distributed Interferometric Fiber-Optic Biosensor for Label-Free Detection of CD44-Expressing Cancer Cells.Biosensors · 2026