Sensors (Basel, Switzerland)

Development of a Wearable Sensor Platform for Fall Risk Assessment and Fall Detection.

Antonella Imperato, Michele Caporaso, Valentina De Pascalis, Giuseppe Di Gironimo, Antonio Lanzotti, Stanislao Grazioso, Angela Palomba, Teodorico Caporaso

ETA Bioengineering S.R.L., Corso Nicolangelo Protopisani 70, 80146 Naples, Italy. · Department of Industrial Engineering-Fraunhofer JL IDEAS, University of Naples Federico II, Piazzale Tecchio 80, 80125 Naples, Italy.

Key points

From the paper's conclusion
  • In this context, the study presents a wearable sensor platform to both predict fall risk and detect falls, based on sensorized clothing integrating inertial measurement units and surface electromyography sensors.

Abstract

Objective: Falls among the elderly constitute a major global public health issue. Research has therefore focused on two complementary areas: fall risk prevention and fall detection. Existing solutions mainly rely on body-attached sensors confined to laboratory settings, whereas recent research has shifted toward wearable e-textiles with non-invasive, long-term-wear sensors. In this context, the study presents a wearable sensor platform to both predict fall risk and detect falls, based on sensorized clothing integrating inertial measurement units and surface electromyography sensors. Methods: Fall risk was estimated from gait parameters extracted during a 10 m walking test as the probability of belonging to a faller (vs. non-faller) group, using a logistic regression model trained on the G-STRIDE dataset, complemented by neuromuscular parameters extracted from sEMG and associated with fall risk. Fall detection, focused on improving pre-impact identification, was framed as a binary classification between activities of daily living and falls, using a reduced Spatio-Temporal Attention Network trained on the FallTL dataset and refined with our own platform's data. Results: The obtained results were: fall-risk assessment, Area Under the Curve = 77.8%, Accuracy = 68.7%; fall detection, Accuracy = 96.7%, F1 Score = 77.3%, lead time = 390 ms. Conclusions: As a single-subject proof of concept, these results support the feasibility of a unified platform integrating objective fall-risk screening and fall event identification, with a predicted time before impact suitable for protective systems intervention; validation on a larger, representative cohort is required before any clinical claim can be made.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers