Sensors (Basel, Switzerland)

Smart Furniture-Embedded Bed-Interaction and Multimodal Room Sensing with Sleep-Aware Hierarchical Fusion for Control-Oriented Bedroom State Recognition.

Xinying Ru, Yumei Bai, Maoxu Wang, Hui Wan

College of Home Furnishing and Art Design, Northeast Forestry University, Harbin 150040, China. · College of Computer and Control Engineering, Northeast Forestry University, Harbin 150040, China.

Key points

From the paper's conclusion
  • This study developed a privacy-preserving bed-centered sensing framework and a sleep-aware hierarchical multimodal fusion model, termed SA-HMF, for recognizing eight operational bedroom states (S0-S7).

Abstract

Reliable control-oriented bedroom state recognition is needed because room-level occupancy sensing cannot distinguish in-bed, out-of-bed, movement, nocturnal bed-exit, and wake-related conditions. This study developed a privacy-preserving bed-centered sensing framework and a sleep-aware hierarchical multimodal fusion model, termed SA-HMF, for recognizing eight operational bedroom states (S0-S7). SA-HMF uses a bed-conditioned, quality-aware asymmetric architecture: bed-load and bed-mounted accelerometry are first encoded into a bed-interaction representation, which then conditions the fusion of bedside indoor environmental quality, room-context, temporal, and sensing quality information. Data were collected from 20 healthy adults across 127 valid participant-nights in one experimental bedroom. The recordings generated 342,684 overlapping 30 s windows using a 10 s stride; these windows were treated as correlated model instances rather than independent observations. Under the primary subject-independent split, SA-HMF achieved 0.925 Accuracy, 0.874 Macro-F1, 0.927 Weighted-F1, and 0.864 Balanced Accuracy. LOSO evaluation yielded a Macro-F1 of 0.852 ± 0.043, with a participant-level 95% confidence interval of 0.833-0.870. Using non-overlapping 30 s windows, SA-HMF retained 0.918 Accuracy, 0.865 Macro-F1, and 0.856 Balanced Accuracy. Retrospective event extraction F1-scores ranged from 0.846 to 0.950. The optimized model was 2.7 MB and required 15.6 ± 3.2 ms per inference. These results support feasibility and transfer to unseen healthy participants within the tested bedroom and sensing configuration. External validation across bedrooms, beds, sensing installations, and populations remains necessary.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers