From the paper's conclusion- This study adopts a typical immersed tunnel project as a case study.
Abstract
The loss of sand foundation often induces differential settlement in immersed tunnel segments, potentially causing structural damage and reducing structural resilience. Accurately assessing the damage characteristics and their effects on resilience during sand foundation loss is essential for ensuring tunnel safety. This study adopts a typical immersed tunnel project as a case study. Long-term structural deformation data acquired by distributed optical fiber sensing technology and sand foundation detection data are adopted to analyze the response characteristics and damage state of the tunnel. A refined three-dimensional tunnel-stratum interaction model is established and validated against monitoring data to investigate mechanical response characteristics, including deformation and bending moment distributions. A redundancy factor is proposed as a quantitative index for tunnel resilience under foundation loss, and a multi-level resilience grading framework is established accordingly. Furthermore, the evolution of tunnel resilience under various displacement recovery ratios, which represent the extent of differential settlement remediation, is investigated using the refined numerical model. Field detection results show that over 50% of the foundation area is affected by loosening or voids. These defects are highly consistent with regions of abnormal structural deformation, leading to a bending-torsional deformation mode, with a maximum joint differential settlement of 106.7 mm. Stress concentration occurs in the tunnel floor above denser sand zones, with a maximum crack width of 0.43 mm. The tunnel is classified as severely damaged (low resilience) based on the proposed standard, with a redundancy factor of 1.59. Bending-torsional deformation and stress concentration are gradually mitigated as the displacement recovery ratio increases. The redundancy factor exhibits a parabolic relationship with the recovery ratio, indicating that tunnel resilience can be restored to a relatively high level when the displacement recovery ratio exceeds 70%. The proposed redundancy factor and grading framework provide quantitative guidance for designing and optimizing resilience improvement strategies following sand foundation loss.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Resilience-based design for subway shield tunnels in soft soils: a perspective from the tunnel–soil systemRailway Engineering Science · 2026
- A construction-stage resilience evaluation model for ground deformation induced by shield tunneling considering recovery timeENGINEERING Structure and Civil Engineering · 2026
- Distributed fibre optic sensing in geotechnics and tunnelling – Excessive data generation or valuable information for construction and operation?Geomechanics and Tunnelling · 2026
- Field performance and deployment challenges of a BOTDA-based distributed fibre optic inclinometer for microtunneling-induced ground deformation monitoringResults in Optics · 2026
- Deformation mechanism of a large-span small-clearance twin tunnel crossing a fault fracture zoneFrontiers in Earth Science · 2026
- CFD–DEM Modeling of Stress–Damage–Seepage Coupling Mechanisms and Support Strategies in Subsea Tunnel ExcavationEng—Advances in Engineering · 2026