Privacy-Preserving Head Pose Estimation System for Measuring Cervical Range of Motion.
Zhuofu Liu, Lichao Zhang, Gaohan Li, Peter W McCarthy
School of Measurement Control Technology and Communication Engineering, Harbin University of Science and Technology, Harbin 150080, China. · Faculty of Life Science and Education, University of South Wales, Treforest, Pontypridd CF37 1DL, UK.
Key points
From the paper's conclusion- The system is fully automatic, requires only a rear-facing camera, effectively preserves patient privacy, and provides accurate cervical posture estimation.
Abstract
Cervical range of motion (CROM) has been used in research and clinically for assessing cervical health. Gold-standard goniometers tend to be cumbersome. However, Inertial Measurement Units (IMUs) or vision-based alternatives demand frequent calibration and/or costly hardware; moreover, the subject is aware of being measured and there is a risk of breaching privacy. In response, we have developed a non-contact HPNet system for head pose estimation (HPE) that can use a rear-facing camera to quantify CROM accurately. A Re-parameterized Visual Geometry Group (RepVGG)-D2se model is employed as the backbone of the network, and a Spatial Feature Enhancement (SCFE) module is incorporated to improve feature extraction. HPNet was evaluated on the large-scale Carnegie Mellon University (CMU) Panoptic dataset, achieving a mean absolute error (MAE) of 3.48°, 3.22°and 3.34° for yaw, pitch and roll respectively. Inter-instrument reliability was excellent for all six cervical movements when compared with the research/clinical-grade CROM device, with intraclass correlation coefficients (ICCs) averaging 0.939. Bland-Altman plots confirmed close agreement between the two methods. Cervical movement trajectory curves further confirmed the concordance between the clinical device and our method. The system is fully automatic, requires only a rear-facing camera, effectively preserves patient privacy, and provides accurate cervical posture estimation. This technology may provide a basis for future applications in neck-disorder screening, remote health monitoring, and personalized musculoskeletal wellness management, although further task-specific clinical validation will be required. To date, HPNet has been validated primarily on a computer-based platform and has not yet been deployed on smartphones. Future work will focus on model lightweighting, mobile deployment, and cross-device adaptation to facilitate its practical implementation on mobile devices.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- SKIA: Spatial-Knowledge Informed Attention for Robust Remote Photoplethysmography under Lower-Face Motion ArtifactsarXiv · 2026
- STAG-Net: Structure-Aware Attention over Landmark Groups for Lightweight Head Pose EstimationarXiv · 2026
- Nostril-Anchored Geometric ROI Projection for Contactless Forehead Skin Temperature Estimation Using Low-Resolution Thermal Imaging.Sensors (Basel, Switzerland) · 2026
- Horizontal nystagmus identification with joint SAM segmentation and time series classificationEuropean Archives of Oto-Rhino-Laryngology · 2026
- GridPulseFormer for Remote Heart Rate Estimation with Regional Temporal Consensus and Robust Waveform ReconstructionInternational Journal of Science and Engineering Applications · 2026
- HAGI++: Head-Assisted Gaze Imputation and Generation.IEEE transactions on visualization and computer graphics · 2026