Long-Term Validation of a Consumer- vs. Industrial-Grade Indoor Radon and Air Quality Monitor at a School in Utah.
John D Beard, Maren M Ball, Christopher Kitras, Philip B Lundrigan
Department of Public Health, Brigham Young University, Provo, UT 84602, USA. · Department of Electrical and Computer Engineering, Brigham Young University, Provo, UT 84602, USA.
Key points
From the paper's conclusion- We collected data about 24 h moving averages of barometric pressure, carbon dioxide (CO2), radon, relative humidity, temperature, and volatile organic compounds (VOC) for approximately 29 weeks in 2024 in each of six rooms in a school in Utah.
Abstract
In recent years, the demand for indoor radon and air quality monitors has increased while more affordable consumer-grade monitors have become available. The aim of our study was to assess the validity of the less expensive, non-calibrated, consumer-grade Lüft (SunRADON LLC, Melbourne, FL, USA) compared to the more expensive, annually and manufacturer calibrated, industrial-grade Model 1028 XP (SunRADON LLC, Melbourne, FL, USA). We collected data about 24 h moving averages of barometric pressure, carbon dioxide (CO2), radon, relative humidity, temperature, and volatile organic compounds (VOC) for approximately 29 weeks in 2024 in each of six rooms in a school in Utah. The mean difference in the co-located Lüfts' and Model 1028 XPs' 24 h moving average radon was -0.05 pCi/L of air (95% confidence interval: -0.24, 0.14, p = 0.50) and the concordance correlation coefficient (CCC) was 0.92. The Lüfts' and Model 1028 XPs' 24 h moving averages were similar for barometric pressure (CCC: 0.87), but the Lüfts' 24 h moving averages were lower than the Model 1028 XPs' for CO2, relative humidity, and VOC and higher for temperature. The Lüft provided valid measurements of 24 h moving averages for barometric pressure and radon, but not for CO2, relative humidity, temperature, and VOC.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Cumulative and real-time performance of consumer-grade electronic radon monitors in a Canadian single-family home over three months.Journal of radiological protection : official journal of the Society for Radiological Protection · 2026
- T-Rex: the transportable radon-222 explorer for environmental or public health studies.Journal of environmental radioactivity · 2026
- Reconsidering indoor radon monitoring strategies in Romanian medical buildings: a data-driven perspective.Frontiers in public health · 2026
- Advancing understanding of temporal performance and behaviour in consumer-grade electronic radon monitors.Radiation protection dosimetry · 2026
- Radon as an Indoor Air Quality Indicator: Ventilation-Based Mitigation, Sensing Technologies, and Data-Driven Approaches: A ReviewApplied Sciences · 2026
- Validation and Correction of PM2.5 Mass Concentrations from Consumer-Grade Personal Exposure and Outdoor Fixed Monitors: A Two-Year Colocation Study in Colorado.ACS environmental Au · 2026