Study on the Influence of Rotation Axis Misalignment of the Exoskeleton Knee Joint on Human Knee Joint Torque.
Changlong Jiang, Xiaorong Guan, Zheng Wang, Dingzhe Li, Long He
Department of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China. · Zhiyuan Research Institute, Hangzhou 310000, China.
Key points
From the paper's conclusion- Considering that, at a misalignment of 0.02 m, the maximum difference in torque in the negative x-axis direction was 54.65% and the assist efficiency in the positive x-axis direction dropped to -5.13%, it is recommended that the misalignment of the exoskeleton knee joint be controlled within 0.02 m.
Abstract
Misalignment between the rotation axis of a lower-limb exoskeleton knee joint and the human knee joint in the sagittal plane introduces additional human-exoskeleton interaction forces, affecting gait and assistance efficiency. This study proposes an equivalent stiffness-damping scheme that simultaneously accounts for the serial characteristics of both the exoskeleton's strapping and human soft tissues, and establishes a human-exoskeleton coupling model based on OpenSim that allows for precise adjustment of the misalignment magnitude along the sagittal coordinate system. Simulation results indicate that the effects of misalignment exhibit significant directional dependence: at a misalignment of 0.05 m, the peak increase in extension torque in the positive y-axis direction reached 38.9%, while the peak increase in flexion torque in the negative x-axis direction reached 211.2%. The trends in human-exoskeleton interaction torque and electromyographic signals measured experimentally were consistent with the simulation results. Considering that, at a misalignment of 0.02 m, the maximum difference in torque in the negative x-axis direction was 54.65% and the assist efficiency in the positive x-axis direction dropped to -5.13%, it is recommended that the misalignment of the exoskeleton knee joint be controlled within 0.02 m. This provides quantitative evidence for the structural design and wear calibration of the exoskeleton.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Dual-loop control of lower-limb exoskeletons using adaptive admittance and nonlinear extended state observer-based active disturbance rejectionRobotica · 2026
- Synergy-informed bilevel optimization reveals joint-specific benefits for realistic exoskeleton torque predictionbioRxiv · 2026
- Misalignment between centre of pressure and musculoskeletal model after inverse kinematics affects lower limb joint kinetics and a method for adjustment.Gait & posture · 2026
- Design and Evaluation of a Trunk–Limb Robotic Exoskeleton for Gait Rehabilitation in Cerebral PalsyBiomimetics · 2026
- A Gait-Conditioned Human-in-the-Loop Optimization Framework Based on Gait-Assistance-Response Relationship Model for Exoskeleton Assistance.Bioengineering (Basel, Switzerland) · 2026
- Multimodal Gait Acquisition and Musculoskeletal Simulation for Subject-Specific Evaluation of Ankle Exosuit Cable Anchor Positioning in Cerebral Palsy.Biomimetics (Basel, Switzerland) · 2026