IMU- and Vision-Based Measurement Techniques for Joint Kinematics: A Narrative Review.
Luca Ceriola, Luca Molinaro, Juri Taborri, Fabrizio Patanè, Ilaria Mileti
Department of Engineering, University Niccolò Cusano, 00166 Rome, Italy. · Department of Theoretical and Applied Sciences (DiSTA), eCampus University, 22060 Novedrate, Italy.
Key points
From the paper's conclusion- This narrative review provides a comparative analysis of IMU- and vision-based approaches for joint kinematics estimation, focusing on biomechanical validation metrics and measurement error.
Abstract
Accurate assessment of joint kinematics is fundamental to biomechanics, rehabilitation, and sports science. Although optical motion capture (OMC) remains the laboratory reference standard for biomechanical validation, its cost, infrastructure requirements, and limited applicability outside controlled environments restrict its broader use. Wearable inertial measurement units (IMUs) and vision-based markerless systems have consequently emerged as complementary alternatives, offering portability, reduced subject preparation, and applicability in ecological settings. Their rapid development, however, has not always been accompanied by an equally rigorous metrological interpretation of performance. This narrative review provides a comparative analysis of IMU- and vision-based approaches for joint kinematics estimation, focusing on biomechanical validation metrics and measurement error. Because the primary literature reports fundamentally different quantities under widely differing experimental conditions, evidence is presented stratified by outcome class, joint, plane of motion, task, and acquisition dimensionality, and values belonging to different outcome classes are not pooled. For sagittal-plane lower-limb angles during level walking in healthy adults, with careful sensor-to-segment calibration and an optoelectronic reference, IMU-based systems show the most consistent performance, with RMSE commonly between 3° and 6°. Vision-based systems achieve comparable accuracy for selected outcomes, particularly spatiotemporal gait parameters and sagittal-plane angles in controlled views, while degrading with occlusion, motion blur, and depth ambiguity. Accuracy is therefore not an intrinsic property of the sensing modality but of the entire measurement chain, including calibration, biomechanical modeling, acquisition geometry, and reporting conventions. Rather than ranking technologies by accuracy alone, the measurement requirements should be derived from the intended application.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Inertial human motion capture: From biomechanics to recent sensor fusion methods and back.Journal of biomechanics · 2026
- Biomechanics-informed inertial tracking achieves the accuracy of marker-based kinematics.Nature communications · 2026
- IMU-based gait analysis methods: a systematic review of techniques for different body locationsFrontiers in Sports and Active Living · 2026
- Application of Machine Learning Techniques in the Measurement of Ground Reaction Force (GRF) waveforms using Inertial Measurement Unit (IMU) Sensors -A Systematic Literature Review.Medical engineering & physics · 2026
- An IMU-Based Wearable Device Utilizing Error-State Kalman Filtering for Motion CaptureApplied Sciences · 2026
- Kinematic validation of an IMU-based 2-segment foot model using optical motion capture and the oxford foot modelScientific Reports · 2026