Validity of the CORE Wearable Sensor During Internal Cooling Induced by Hyperhydration with Cold Water at Rest.
Eric D B Goulet, Antoine Jolicoeur Desroches, Thomas A Deshayes, Timothée Pancrate, Marc Elouann Pidoux, Antoine Carmichael, Tristan Etienne
Faculty of Physical Activity Sciences, University of Sherbrooke, Sherbrooke, QC J1K 2R1, Canada.
Key points
From the paper's conclusion- These results raise concerns about the ability of the CORE to detect changes in TC induced by a hyperhydration protocol generating a substantial heat sink.
Abstract
Pre-exercise internal cooling through cold-water-induced hyperhydration may attenuate increases in core body temperature (TC) and improve endurance performance. Quantifying the extent of reduction in TC induced by hyperhydration is important for optimizing its timing before exercise. We compared TC values obtained from a wearable sensor, the CORE, with those of a gastrointestinal temperature telemetric sensor (GTS) during hyperhydration. Eleven participants (two women; age: 24 ± 4 yrs) completed a 120 min seated period where they consumed, over the first 60 min, four boluses of 4 °C water (7.5 mL · kg fat-free mass [FFM]-1), each containing 0.35 g · kg FFM-1 of glycerol. Measures of TC were taken every 20 min with both sensors. According to the GTS, hyperhydration induced a peak TC decline of -0.76 ± 0.31 °C at min 60; at this time, the change in TC from baseline estimated by the CORE was -0.09 °C ± 0.20 °C. The greatest decline in TC detected by the CORE was -0.11 ± 0.19 °C. Bland and Altman analyses revealed that average TC declines of -0.1, -0.2, -0.3, -0.4, -0.5 and -0.6 °C from baseline were associated with TC values estimated by the CORE that were respectively +0.29, +0.41, +0.57, +0.65, +0.77 and +0.89 °C higher than the GTS. An intraclass correlation coefficient of 0.12 suggested poor agreement between instruments. These results raise concerns about the ability of the CORE to detect changes in TC induced by a hyperhydration protocol generating a substantial heat sink.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Validity and Reliability of Wearable Heat Stress Monitors in Firefighters During Exercise-Induced Hyperthermia.Medicine and science in sports and exercise · 2026
- A Comprehensive Review of Non-Invasive Core Body Temperature Measurement TechniquesSensors · 2026
- Effects of during-exercise oral hydration strategies on endurance performance and thermophysiological strain: a systematic review with meta-analysis.Frontiers in nutrition · 2026
- Temperature-comfort discordance and an expert-informed perioperative thermal-management framework in robotic urologic surgery: a sequential multimethod study.Journal of robotic surgery · 2026
- Effect of pre-cooling by cold-water immersion on continuous sweat conductivity kinetics during submaximal exercise in the heat.Journal of thermal biology · 2026
- Efficacy of a Meta-Analysis-Recommended Immersion Protocol vs. Field-Practical Cold-Water Immersion Protocol for Performance Recovery: A Randomized Crossover Trial.Journal of strength and conditioning research · 2026