Sensors (Basel, Switzerland)

Research on Vibration Signal Processing and Fault Diagnosis Algorithms for High-Pressure Quintuplex Pumps.

Zewei Liu, Yuanchen Zhu, Zhigang Zhang, Tao Zhang

School of Mechanical Engineering, Sichuan University, Chengdu 610065, China.

Key points

From the paper's conclusion
  • These results demonstrate that VICA-DA-ViT can effectively improve the robustness of small-sample cross-condition fault diagnosis for high-pressure quintuplex pumps.

Abstract

High-pressure quintuplex pumps are key components in oil and gas drilling systems, but their fault diagnosis remains challenging due to severe inter-cylinder vibration crosstalk, operating-condition variability, and limited labeled samples. To address these issues, this paper proposes an integrated vibration-based diagnostic framework, termed VICA-DA-ViT. First, a VMD-FastICA-based blind source separation strategy is used to suppress inter-cylinder crosstalk and extract more discriminative vibration components from mixed signals. Then, angular-domain resampling and normalization are applied to reduce speed-induced non-stationarity and improve cycle consistency. The processed one-dimensional signals are further converted into two-dimensional GAF-RP representations, where GAF captures global temporal correlations and RP provides complementary recurrence information. Finally, a ViT-based domain-adaptive diagnostic framework is constructed for unsupervised cross-condition diagnosis by integrating domain-adversarial pretraining, weighted bidirectional sample pairing, and Gaussian-mixture-based confidence filtering around a standard Vision Transformer backbone. Rather than modifying the internal architecture of ViT, the proposed framework improves cross-condition generalization by combining signal decoupling, angular-domain alignment, and domain-adaptation strategies for high-pressure quintuplex pump fault diagnosis. Experiments on a quintuplex pump dataset under multiple operating conditions show that the proposed framework achieves an average cross-condition accuracy of 87.42%, outperforming CD-Trans by 11.94%. These results demonstrate that VICA-DA-ViT can effectively improve the robustness of small-sample cross-condition fault diagnosis for high-pressure quintuplex pumps.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers

Research on Vibration Signal Processing and Fault Diagnosis Algorithms for High-Pressure Quintuplex Pumps — Science Skim