Velocity-Sensor-Based Dual-ESO Reconstruction for Feedforward-Feedback Low-Frequency Active Micro-Vibration Isolation.
Zhenyu Fan, Yong Xie, Yuzhang Zhu, Yi Le, Yifei Zhang, Rui Xiu, Xindong Liang, Liang Zhang,
Key Laboratory of Space Active Opto-Electronics Technology, Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai 200083, China. · University of Chinese Academy of Sciences, Beijing 100049, China.
Key points
From the paper's conclusion- These results demonstrate that low-frequency active micro-vibration isolation can be achieved using only velocity measurements, without additional displacement sensors.
Abstract
Low-frequency base vibration transmitted through supporting platforms can degrade the stability of precision payloads, optical instruments, and inertial measurement systems. In velocity-sensor-based active isolation platforms, displacement-related feedback states are unavailable. Direct velocity integration can drift under sensor bias, while raw lower-platform velocity feedforward can introduce measurement noise and out-of-band components. This paper proposes a dual extended state observer (ESO) reconstruction method combining equivalent-displacement feedback and lower-platform feedforward. The upper-platform ESO reconstructs feedback velocity and a bounded equivalent-displacement state, while the lower-platform ESO provides a smoothed velocity reference for feedforward compensation. The method was implemented on a plate-type active vibration isolation platform and evaluated using lower-to-upper-platform acceleration transmissibility over 0.1-10 Hz. Across three repeated 200 s records, the proposed ESO feedback-feedforward condition achieved an integrated input-output suppression ratio of 38.67±0.46 dB, reduced the upper-platform output acceleration RMS to (1.31±0.09)×10-7 g, and provided a 48.92±2.12 dB RMS reduction relative to the passive baseline. Direct nominal-measured comparisons further showed that the reduced model captured the dominant passive and feedback-controlled dynamics. These results demonstrate that low-frequency active micro-vibration isolation can be achieved using only velocity measurements, without additional displacement sensors.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Composite Active Disturbance Rejection Vibration Isolation Control Based on Compensation for Unknown DisturbanceStructural Control and Health Monitoring · 2026
- Integrated Dynamic Modeling and Ground Test Validation for Spacecraft Micro-Vibration Suppression Considering Disturbance, Isolation, and Pointing ControlSensors · 2026
- An integrated low-friction low-resonance passive vibration isolator: tunable nonlinear stiffness, damping, and inertiaNonlinear Dynamics · 2026
- Active Maglev Vibration Isolation via a Slim Halbach Array Electromagnetic ActuatorAerospace · 2026
- Disturbance Rejection for Periodic Scanning of Inertially Stabilized Platforms: An Iterative-Learning-Embedded Finite-Time Extended State Observer ApproachActuators · 2026
- Quasi-zero-stiffness vibration isolation: A comprehensive review of design principles and engineering applicationsInternational Journal of Non-Linear Mechanics · 2026