A Cascaded Quantized Spiking Neural Network for Real-Time ECG Arrhythmia Detection on Edge Hardware
O. O. Banjo, Behnaz Ghoraani
Florida Atlantic University
Key points
From the paper's conclusion- These results demonstrate quantized SNNs as a practical solution for real-time edge arrhythmia monitoring that operates independently of cloud connectivity—removing the network-dependent latency, connectivity-dropout failure modes, and continuous-transmission energy burden that constrain current wearable monitors and, to our knowledge, represent one of the first systematic studies of loss-function
Abstract
Wearable ECG monitors enable continuous cardiac surveillance, but most still rely on cloud-based analysis with limited on-device support for multi-class arrhythmia detection. Spiking neural networks (SNNs) are promising for low-power edge inference, yet it remains unclear how class-imbalance loss design interacts with RR-interval features in directly trained quantized SNNs, and FPGA validation in this setting is largely unexplored. We propose a quantized convolutional spiking neural network (QCSNN) for real-time arrhythmia detection on resource-constrained hardware. The model uses a dual-head architecture that jointly trains binary and four-class classifiers, subsequently reorganized into a cascaded pipeline that routes only abnormal beats to the second stage. At inference, beats classified as Normal exit at Stage 1; only beats classified as Abnormal are routed to the four-class head, so the bulk of the inference cost is absorbed by Stage 1. We evaluate two loss functions, Cross-Entropy and Focal Loss, under four RR-feature routing strategies. Without RR features, Focal Loss improves macro F1 by 2.3–2.5% over Cross-Entropy (mean Δ = +0.013 in Stage-2 macro F1; Wilcoxon two-sided p = 0.031). With RR features, this advantage largely disappears (Wilcoxon two-sided p ≥ 0.219 at all RR routings); meanwhile, RR features at the strongest routing improve Stage-2 macro F1 by +0.028 to +0.034 depending on loss function—a gain that exceeds the entire Focal-Loss-over-Cross-Entropy advantage, suggesting that RR features provide discriminative information that compensates for class imbalance at the input level. Based on clinically prioritized sensitivity, the CE:RR→Both configuration was deployed on a PYNQ-Z2 FPGA, achieving 99.02% cascaded accuracy, 11.54 ms per-beat latency, and 0.33 W accelerator power—a 31.66× power reduction and 4.01× energy reduction versus GPU inference, within 1% macro F1. These results demonstrate quantized SNNs as a practical solution for real-time edge arrhythmia monitoring that operates independently of cloud connectivity—removing the network-dependent latency, connectivity-dropout failure modes, and continuous-transmission energy burden that constrain current wearable monitors and, to our knowledge, represent one of the first systematic studies of loss-function/RR-feature interactions in directly trained SNN arrhythmia classification and one of the first FPGA deployments of a fully quantized, directly trained SNN for multi-class ECG arrhythmia detection. All code generated and used in this study has been made publicly available.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- All-Spiking ECG Analysis for Arrhythmia Classification on Low-Power FPGAIEEE Sensors Journal · 2026
- Neural Architecture Search-Based ECG Classification for Low-Power Edge Deployment in IoT Healthcare Systems.IEEE journal of translational engineering in health and medicine · 2026
- ArrythML-II: An Optimized TinyML Framework for ECG Arrhythmia Detection and Multi-Class Beat Classification on Wearable DevicesarXiv · 2026
- Real-Time Cardiac Arrhythmia Classification Using TinyML on Ultra-Low-Cost Microcontrollers: A Feasibility Study for Resource-Constrained EnvironmentsBioengineering · 2026
- Neuromorphic Cardiac Sensing: A Bio-Inspired Spiking Neural Network with Sensory-Adaptive Encoding for Energy-Efficient Arrhythmia Detection from ECG and PPG Signals.Biomimetics (Basel, Switzerland) · 2026
- TinyML-Based Photoplethysmography (PPG) Analysis for Atrial Fibrillation Detection.Sensors (Basel, Switzerland) · 2026