Design Principles for EMAT Coils Based on Lorentz Force
Jhon Padilla, Daniel Bernal, Mauricio Barrios Castellanos, Miguel Rios, Juan Argüello, Juan Mantilla, Luis Angel
Corporación para el Desarrollo Sostenible del Urabá · Universidad Pontificia Bolivariana
Key points
From the paper's conclusion- Key design parameters are explicitly addressed: number of turns N, outer and inner radii R and r0, track width w and spacing s for spiral coils, and meander length and inter-trace distance for meander-line coils.
Abstract
EMAT technology for Non Destructive testing is an important method for materials testing in several industries. In EMAT tools, a key issue is the EMAT coils design and implementation. Depending on the type of inspection, the coil type should be selected, and then, its dimensions should be calculated. This paper describes a methodology to select, design and implement EMAT coils based on Lorentz Force for applications such as thickness measurement and crack detection. Unlike previous works that focus on a single coil topology, this study integrates coil selection, dimensional design, COMSOL-based radiation-pattern simulation and experimental validation within a single workflow. Four Lorentz-force coil designs are covered: PCB spiral (CSPCB), 3D-printed spiral (CS3D), PCB meander-line (CMPCB) and 3D-printed meander-line (CM3D). Key design parameters are explicitly addressed: number of turns N, outer and inner radii R and r0, track width w and spacing s for spiral coils, and meander length and inter-trace distance for meander-line coils. Simulation verification is performed in COMSOL Multiphysics by evaluating the von Mises stress along a semicircular path around the coil to obtain the angular radiation pattern. Experimentally, polar radiation patterns are measured at 500 kHz, 1.9 MHz and 4 MHz on a steel specimen, matching the simulation frequencies, with maximum amplitudes of 32.2, 46.4, 47.9 and 10.6 mV for CSPCB, CS3D, CMPCB and CM3D, respectively, showing consistent agreement between simulated and measured lobe shape and directivity. This work also uses an analogy with radio frequency antennas to better understand the operation of coils through the concept of radiation patterns, in this case in solid materials such as steel.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Advances in Rayleigh and shear-horizontal EMAT systems for NDT and SHM: A reviewNDT & E International · 2026
- Development of an Integrated EMAT With Longitudinal and Orthogonal Polarized Shear Waves for Plane Stress MeasurementIEEE Sensors Journal · 2026
- Solid-state non-array vector-bias-field EMAT for arbitrary-direction ultrasonic guided-wave measurement and imagingNondestructive Testing And Evaluation · 2026
- Enhancement of Signal Amplitude of Magnetostrictive-Based EMAT with Terfenol-D Coating for Stainless-Steel SpecimensElectronics · 2026
- Dual-frequency EMAT for amplitude-modulated Rayleigh wave mixing: Theory, implementation, and thermal damage detectionMeasurement · 2026
- High-Resolution 3D Micro-CT Database of Transcranial Magnetic Stimulation (TMS) Coils for More Accurate Modelling, Technology Benchmarking, and Progress in Coil DesignarXiv · 2026