Machine Learning-Enhanced Evaluation of Handheld Laser-Induced Breakdown Spectroscopy (LIBS) Analytical Performance for Multi-Element Analysis of Rock Samples
N. Senesi, O. De Pascale, Ignazio Allegretta, Roberto Terzano, Bruno Marangoni
Institute for the Science and Technology of Plasmas · University of Salento
Key points
From the paper's conclusion- The results achieved suggested that the spectral resolution was the key factor determining the performance of multivariate LIBS calibrations.
Abstract
Handheld laser-induced breakdown spectroscopy (hLIBS) can be considered one of the most recent techniques for rock characterization in situ. Handheld LIBS devices are useful tools for providing “fit for purpose” qualitative and quantitative geochemical data. The analytical performance of hLIBS instruments varies significantly between similar instruments from different manufacturers. This study employed two commercial hLIBS instruments, both making use of noise reduction and multivariate partial-least-squares (PLS) calibration. Model validation was performed using the Leave-One-Out Cross-Validation (LOOCV) method. The Random Forest (RF) and Artificial Neural Network (ANN) algorithms were also employed as complementary approaches to PLS modeling, with the goal of exploring potential nonlinear relationships between spectral intensities and reference analyte concentrations. A comparison was also made with the most basic and commonly used approach, univariate analysis, demonstrating that multivariate methods achieve superior performances. To evaluate the predictive performance and quantification capability of the acquired LIBS spectra, the Pearson’s coefficient (R2) and root-mean-square error (RMSE) were employed in the analysis of 21 diverse certified geochemical reference materials (CRMs). The results achieved suggested that the spectral resolution was the key factor determining the performance of multivariate LIBS calibrations. The PLS model proved to be satisfactory for analyses performed by the higher-spectral-resolution instrument, whereas complementary algorithms were necessary to achieve better results with the lower-spectral-resolution instrument.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Quantitative analysis of major elements in logging cuttings using laser-induced breakdown spectroscopy and a dual-scale attention residual network.Analytical methods : advancing methods and applications · 2026
- Sample identification using a laser induced breakdown spectroscopy (LIBS) spectral database based on molecular and elemental fingerprintsSpectrochimica Acta Part B Atomic Spectroscopy · 2026
- Laser-induced breakdown spectroscopy: an efficient analytical technique for qualitative and quantitative analysis [Invited]Journal of the Optical Society of America B · 2026
- Towards Reconstructable CF-LIBS Quantification: A Perspective on Reporting, Validation, and ReproducibilityChemosensors · 2026
- Signal enhancement in laser-induced breakdown spectroscopy for improved sensitivity and detection limits: Mechanisms and prospects.The Review of scientific instruments · 2026
- A Specimen-Separated Machine Learning Benchmark Toward Real-Time Tissue-Type Identification in Guided Surgery Using Ex Vivo Bovine Laser-Induced Breakdown Spectroscopy.Sensors (Basel, Switzerland) · 2026