Adaptive Layer-Dependent Threshold Function for Wavelet Denoising of ECG and Multimode Fiber Cardiorespiratory Signals
Yuni Zhang, Kaimin Yu, Chufeng Huang, Ruiting Qu, Zhichun Fan, Peibin Zhu, Wen Chen, Jianzhong Hao
Jimei University · Fuzhou University
Key points
From the paper's conclusion- The method also demonstrates excellent performance on real ECG and optical fiber cardiopulmonary signals, preserving key diagnostic features like QRS complexes and ST segments while effectively suppressing artifacts.
Abstract
This paper proposes an adaptive layer-dependent threshold function (ALDTF) for denoising electrocardiogram (ECG) and multimode optical fiber-based cardiopulmonary signals. Based on wavelet transform, the method employs a layer-dependent threshold function strategy that utilizes the non-zero periodic peak (NZOPP) of the signal's normalized autocorrelation function to adaptively determine the optimal threshold for each decomposition layer. The core idea applies soft thresholding at lower layers (high-frequency noise) to suppress pseudo-Gibbs oscillations, and hard thresholding at higher layers (low-frequency noise) to preserve signal amplitude and morphology. The experimental results show that for ECG signals contaminated with baseline wander (BW), electrode motion (EM) artifacts, muscle artifacts (MA), and mixed (MIX) noise, ALDTF outperforms existing methods-including SWT, DTCWT, and hybrid approaches-across multiple metrics. It achieves a ΔSNR improvement of 1.68-10.00 dB, ΔSINAD improvement of 1.68-9.98 dB, RMSE reduction of 0.02-0.56, and PRD reduction of 2.88-183.29%. The method also demonstrates excellent performance on real ECG and optical fiber cardiopulmonary signals, preserving key diagnostic features like QRS complexes and ST segments while effectively suppressing artifacts. ALDTF provides an efficient, versatile solution for physiological signal denoising with strong potential in wearable real-time monitoring systems.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparative Performance Assessment of Stationary Wavelet Transform Configurations for ECG Denoising Using Multi-Metric Evaluation Framework.Sensors (Basel, Switzerland) · 2026
- Multi-Feature Adaptive Variational Mode Decomposition for Wearable ECG DevicesBiosensors · 2026
- Adaptive Electrocardiogram (ECG) Signal Denoising Using Particle Swarm Optimization-Based Non-Local Means (NLM) Filtering.Biomedical physics & engineering express · 2026
- FG-DPUNet: a feature-aware gating dual-path U-Net for ECG motion artifact removal with waveform integrityFrontiers in Signal Processing · 2026
- TFCDiff: Robust ECG Denoising via Time-Frequency Complementary Diffusion.IEEE journal of biomedical and health informatics · 2026
- Comparative evaluation of filtration techniques for ECG signal denoising with emphasis on stationary wavelet transformScientific Reports · 2025