Preliminary Clinical Case Series for Evaluation of a Novel Bi-Dimensional Archwire During Miniscrew-Supported En-Masse Retraction of the Maxillary Anterior Teeth.
Abdulmalek M H Almasri, Mohammad Y Hajeer, Ahmad S Burhan, Safwan Jaber
Department of Orthodontics, Faculty of Dentistry, University of Damascus, Damascus P.O. Box 16046, Syria. · Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Arab International University, Daraa P.O. Box 16046, Syria.
Key points
From the paper's conclusion- This prospective clinical case series aimed to provide an initial clinical evaluation of a novel laser-welded bi-dimensional archwire designed for miniscrew-supported en-masse retraction in adult patients with Class II Division 1 malocclusion.
Abstract
BACKGROUND/OBJECTIVES: Efficient en-masse retraction of the maxillary anterior teeth requires adequate anchorage control while maintaining acceptable incisor torque. This prospective clinical case series aimed to provide an initial clinical evaluation of a novel laser-welded bi-dimensional archwire designed for miniscrew-supported en-masse retraction in adult patients with Class II Division 1 malocclusion. METHODS: Six patients requiring extraction of the maxillary first premolars were treated using a custom-made stainless-steel archwire consisting of a 0.019 × 0.025-inch anterior segment and 0.016 × 0.022-inch posterior segments. Retraction was performed using nickel-titanium closed-coil springs delivering approximately 250 g of force per side. The primary outcome was the monthly rate of maxillary anterior retraction measured on three-dimensional digital models. The secondary outcome was the change in maxillary incisor torque assessed on lateral cephalometric radiographs using the bracket-archwire angle. RESULTS: Repeated measurements showed no statistically significant systematic error, with method errors ranging from 0.14 to 0.31 mm for linear variables and from 0.72° to 1.08° for angular variables; intraclass correlation coefficients ranged from 0.91 to 0.97. The overall mean retraction rate was 0.97 ± 0.05 mm/month, and the mean retraction duration was 5.78 ± 0.79 months. The mean change in maxillary incisor torque was 7.08 ± 1.29°. CONCLUSIONS: Within the limitations of this six-participant clinical case series, the novel bi-dimensional archwire was associated with a relatively stable observed rate of anterior retraction, although a measurable change in the bracket-archwire angular relationship remained. These descriptive findings should be regarded as preliminary and hypothesis-generating and require confirmation in adequately powered controlled studies. TRIAL REGISTRATION: ClinicalTrials.gov, NCT07664215; retrospectively registered on 24 June 2026.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Comparison of En Masse Retraction and Two-Step Retraction Mechanics in Class I Bimaxillary Protrusion: A Retrospective Comparative Study.Cureus · 2026
- A comparative evaluation of corticotomy-assisted and conventional maxillary anterior en-masse retraction: A clinical study.Bioinformation · 2026
- Intra-jaw versus inter-jaw mini-implant anchored total maxillary arch distalization compared with extraction-based en-masse retraction in adult class II division 1 malocclusion patients: A randomized controlled trial.International orthodontics · 2026
- Effect of additional mechanics used in intrusion with clear aligners on the movement of mandibular incisors: a finite element analysisBMC Oral Health · 2026
- Methods of incisor inclination control during the non-accelerated retraction of upper anterior teeth with fixed orthodontic appliances: a systematic review and meta-analysis.BMC oral health · 2026
- Comparison of Maxillary Canine Retraction Rate Among Conventional (Labial) vs. Dual (Simultaneous Labial and Palatal) Mechanics During Fixed Orthodontic Treatment-A Randomised Controlled Trial.Orthodontics & craniofacial research · 2026