Cardiac Implantable Electronic Device Infections at a Tertiary Center in Southern Chile (2015-2021): A Retrospective Cohort Study.
Alban Landeros, Cheryld Mutel, Mauricio Soto, Luis Quiñiñir
Department of Internal Medicine, Faculty of Medicine, Universidad de La Frontera, Araucanía Region, Temuco 4811230, Chile.
Key points
From the paper's conclusion- The clinical and microbiological profile of CIED infections in this single-center southern Chilean cohort was broadly consistent with international series. Per-procedure proportions for ICDs and CRT devices were numerically higher than those for pacemakers, but the retrospective design, a procedure-based denominator including replacements and upgrades, and incomplete echocardiographic and microbiological workup preclude formal comparison with time-to-event registries; these device-specific findings should be regarded as exploratory and hypothesis-generating. The findings identify concrete, locally actionable targets: more systematic microbiological sampling, broader pre-procedural and diagnostic echocardiography (including transesophageal studies), and strengthened long-term follow-up of CIED carriers.
Abstract
BACKGROUND/OBJECTIVES: Cardiac implantable electronic device (CIED) infections are infrequent but clinically significant, and Latin American-particularly Chilean-data remain scarce. We aimed to describe the clinical and microbiological profile, complications, mortality, and local infection burden of CIED infections at a tertiary center in southern Chile. METHODS: This was a retrospective descriptive cohort study of all patients treated for CIED infection at Hospital Dr. Hernán Henríquez Aravena between January 2015 and December 2021. Crude per-procedure infection proportions were calculated using locally implanted devices (primary implants, generator replacements, and upgrades) as the denominator; because annual implant volumes and individual follow-up times were not retrievable, only exploratory approximate rates per 100 patient-years were derived under strong assumptions and were not used for formal comparison. RESULTS: Fifty-four patients were included (77.8% men; mean age 69 ± 14 years). Predominant comorbidities were arterial hypertension (79.6%), heart failure (40.7%), atrial fibrillation (27.8%), and type 2 diabetes mellitus (24.1%). Pacemakers accounted for 59.3% of infections, and late-onset cases predominated (48.2%). The overall per-procedure infection proportion was 1.4% (95% confidence interval [CI] 1.1-1.9%) and was numerically higher for implantable cardioverter-defibrillators (ICDs; 5.5%) and cardiac resynchronization therapy (CRT) devices (4.3%) than for pacemakers (1.1%). Coagulase-negative Staphylococcus (43.2%) and Staphylococcus aureus (24.3%) were the leading isolates, although microbiological sampling was incomplete (available in 68.5%). Complete system extraction was attempted in all patients and achieved in all but one case; recurrence occurred in 9.3% and in-hospital mortality in 1.9%. CONCLUSIONS: The clinical and microbiological profile of CIED infections in this single-center southern Chilean cohort was broadly consistent with international series. Per-procedure proportions for ICDs and CRT devices were numerically higher than those for pacemakers, but the retrospective design, a procedure-based denominator including replacements and upgrades, and incomplete echocardiographic and microbiological workup preclude formal comparison with time-to-event registries; these device-specific findings should be regarded as exploratory and hypothesis-generating. The findings identify concrete, locally actionable targets: more systematic microbiological sampling, broader pre-procedural and diagnostic echocardiography (including transesophageal studies), and strengthened long-term follow-up of CIED carriers.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- Age-stratified clinical phenotypes of cardiac implantable electronic device infections: a 20-year retrospective cohort study.BMC cardiovascular disorders · 2026
- Long-term incidence of infective endocarditis according to the type of cardiac implantable electronic device: a nationwide comparison with moderate- and high-risk patient groups.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026
- Trends in cardiac implantable electronic device infections: 2015 to 2019BMC Cardiovascular Disorders · 2026
- Beyond the Pocket: Clinical, Routine Biomarker, and Microbiological Associations with Systemic Versus Localized Cardiovascular Implantable Electronic Device Infection.Diagnostics (Basel, Switzerland) · 2026
- Cardiac device related infective endocarditis (CDRIE): the POL-ENDO (Polish infective endocarditis registry) substudyEuropean Heart Journal · 2026
- Prevalence of bloodstream infection with different microorganisms in patients with cardiac implantable electronic devices - a Danish nationwide cohort studyEuropean Heart Journal · 2026