Optimization of [11C]Choline Synthesis on the TracerMaker Module for Primary Hyperparathyroidism PET Imaging
Tin H. Huynh, Anders B. A. Andersen, Valdemar L. Andersen, Charlotte B. Christensen, Lars T. Jensen, Tri H. V. Huynh
Key points
From the paper's conclusion- These findings demonstrate a practical route for [11C]choline synthesis optimization to meet the growing clinical demand for PET imaging of PHPT.
Abstract
Positron emission tomography (PET) using [11C]choline has recently gained clinical importance for localizing autonomous adenomas in primary hyperparathyroidism (PHPT), offering superior diagnostic accuracy and sensitivity compared to conventional [99mTc]sestamibi scintigraphy. To meet rising clinical demand using existing infrastructure, this study evaluated three key parameters to optimize the in-house [11C]choline synthesis on a TracerMaker module using [11C]CH4 as the radioactive precursor, which originally yielded 3.19 ± 0.69 GBq at end of synthesis (EOS). Three critical synthesis steps were systematically evaluated: (1) cyclotron irradiation time, (2) precursor (dimethylaminoethanol, DMAE) loading volume across Sep-Pak Accell CM cartridges, and (3) purification wash volumes. Extending irradiation time from 25 to 42 min produced no significant increase in EOS yield. Increased DMAE loading volumes up to 300 µL across 1–3 serially connected 130 mg sorbent cartridges doubled the EOS yield but elevated residual DMAE levels in the final product. Increased wash volumes of ethanol and water failed to improve purification efficiency; however, substituting the multi-cartridge system with a single higher-mass sorbent cartridge (360 mg) achieved effective DMAE removal while maintaining high EOS yield (6.46 ± 0.31 GBq). These findings demonstrate a practical route for [11C]choline synthesis optimization to meet the growing clinical demand for PET imaging of PHPT.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Trifunctional, Rare-Earth Theranostic Chelator Platform to Enable Diagnostic Nuclear Imaging, Surgical Resection, and RadiotherapyJournal of the American Chemical Society · 2025
- Comparative performance of 11C-methionine and 11C-choline PET/CT in primary hyperparathyroidism: Impact of adenoma weight on PET detectability.European journal of nuclear medicine and molecular imaging · 2026
- Design, radiochemical characterization and preclinical evaluation of a 64Cu-labeled 2-methyl-8-hydroxyquinoline complex as a PET tracer.Annals of nuclear medicine · 2026
- Real-world use of [18 F]fluorocholine PET/CT as a second-level imaging modality in primary hyperparathyroidism: a two-center observational study.EJNMMI research · 2026
- Recent advances in [11C]HCN radiochemistry and applications to (pre)clinical PET imaging.Nuclear medicine and biology · 2026
- Reliable One-Pot Automated Preparation of [11C]SL25.1188 for Use in Clinical Imaging Studies.Journal of labelled compounds & radiopharmaceuticals · 2026