Processes

Perturb-and-Observe PTO Force Control for Grid-Connected Wave Energy Converters with BESS-Based Power Smoothing

Mohamed Abdi Jama, Addy Wahyudie

Computational

Key points

From the paper's conclusion
  • The results quantify a clear, multi-criteria trade-off and show that model-assisted PTO parameter adaptation can achieve competitive energy capture relative to a scaled model-based reactive-control benchmark within a grid-connected system.

Abstract

Wave energy converters (WECs) must simultaneously maximize the energy absorbed from an irregular sea and deliver it to the grid as a smooth, standards-compliant power flow—two objectives that conventional PTO controllers address only partially. This paper proposes an adaptive perturb-and-observe (P&O) power-take-off (PTO) force-control strategy for a grid-connected, battery-supported heaving point-absorber WEC, and evaluates it within a complete wave-to-grid model. Unlike damping-only P&O schemes, the proposed coordinated dual-objective algorithm adaptively tunes both the PTO damping and the reactive stiffness coefficient online, using a Hilbert-envelope-based absorbed-power objective and a normalized excitation-force–velocity alignment metric, thereby retuning the device towards resonance without requiring hydrodynamic impedance information for PTO parameter optimization or wave-force prediction. The machine-side converter, a DC link with an integrated battery energy storage system (BESS), and a grid-side converter complete the wave-to-grid chain. The proposed dual-parameter P&O (DP-PO) strategy is benchmarked against damping-only P&O (D-PO), FLL-based resistive loading (FLL-RL), and scaled approximate complex-conjugate (S-ACC) control across three JONSWAP sea states. DP-PO attains the highest capture width ratio in SS1 and SS2 (up to 0.380) and achieves comparable performance to S-ACC in SS3 (0.253 versus 0.257), at the cost of higher peak PTO force, buoy excursion, and storage utilization, while the BESS-supported system achieves a power smoothing index of 0.855–0.925 under DP-PO across the investigated sea states. The results quantify a clear, multi-criteria trade-off and show that model-assisted PTO parameter adaptation can achieve competitive energy capture relative to a scaled model-based reactive-control benchmark within a grid-connected system.

Read the paper

Discussion

Science Skim's AI key points, plus readers' public thoughts

Readers' thoughts

No reader thoughts yet.

Related papers