Homotopy-Based Workflow for Efficient Model Parameter Determination of Versatile-Chromatographic Systems
Marcel Broocks, Jessica Lütge, Andreas Potschka, Jochen Strube
Key points
From the paper's conclusion- The results demonstrate that homotopy-based optimization provides a stable and transferable foundation for mechanistic model calibration and supports predictive, model-based process development in preparative and manufacturing chromatography.
Abstract
Process modelling is an increasingly important tool in pharmaceutical manufacturing process design and operation. As a versatile unit operation, chromatography is well suited to exemplify general modeling methods across different unit operations and a broad variety of molecular classes. Accurate identification of phase-equilibrium in general, for any unit operation, and especially adsorption isotherm parameters, is essential for reliable mechanistic chromatography modeling, yet conventional inverse optimization approaches often struggle with nonlinear parameter spaces, local minima, and numerical instability. This work presents a homotopy-based optimization workflow that enables robust and reproducible estimation, exemplified by isotherm determination in ion-exchange (IEX) and reversed-phase (RP) chromatography. Experimental chromatograms of the main component are characterized using a new analytical linear amplitude (LA) peak model, which provides a consistent reference for constructing a continuous homotopy path between simulated and experimental peak shape parameters. Along this path, the isotherm parameters of steric mass action (SMA) and Langmuir models are iteratively optimized using a Levenberg–Marquardt scheme embedded in a differential-algebraic column model. To ensure numerical stability, the squared residuals are scaled by the Median Absolute Deviation (MAD), yielding a robust and scale-independent error measure. The approach is generally applicable for any adsorption isotherm system. The workflow reliably converges to a producible and physically meaningful parameter set, independent of the chosen initial values, and accurately reproduces chromatographic profiles across multiple gradients using a unified parameter set. In addition, selective weighting of LA shape parameters enables targeted refinement of critical peak features without compromising the fit quality of other gradients. The results demonstrate that homotopy-based optimization provides a stable and transferable foundation for mechanistic model calibration and supports predictive, model-based process development in preparative and manufacturing chromatography.
Read the paper
Discussion
Science Skim's AI key points, plus readers' public thoughts
Readers' thoughts
No reader thoughts yet.
Related papers
- A Three-Level Hierarchical Calibration Framework Enables Robust Mechanistic Modeling of Multi-Component Protein Ion-Exchange Chromatography.Biotechnology and bioengineering · 2026
- Bridging data and theory: hybrid modelling for pharmaceutical crystallisation process development.Digital discovery · 2026
- Surrogate chromatographic models and the solvation parameter modelJournal of Chromatography Open · 2025
- Response Surface Methodology-driven RP-HPLC-PDA Approach to Analytical Method Development, Validation, and Quantitation of Ixazomib in its Pharmaceutical Formulations.Drug metabolism and bioanalysis · 2026
- On the impact of mechanistic model quality and data availability in hybrid model developmentComputers & Chemical Engineering · 2025
- Investigation into the ability of Gaussian processes to faithfully reconstruct Chromatographic Response Function surfaces.Journal of chromatography. A · 2026